3T MRI单指数与双指数DWI全病灶直方图分析鉴别肺癌与良性肺病变

Whole-lesion histogram analysis of mono-exponential and bi-exponential diffusion-weighted imaging in differentiating lung cancer from benign pulmonary lesions using 3 T MRI.
PubMed 文献 · Clin Radiol · 2021-08-08

肺癌的ADC均值、ADC10th、D均值、D10th显著低于良性病变,ADC偏度与D偏度显著不同;D10th以0.453×10⁻³ mm/s为阈值鉴别诊断敏感度78.12%、特异度82.35%、准确率79.6%。

要点

  • 全病灶直方图D10th有助于肺癌与良性肺病变的鉴别,阈值0.453×10⁻³ mm/s。
  • 肺癌ADC均值、ADC10th、D均值、D10th均低于良性病变,偏度更高。
  • D10th鉴别效能较稳健,敏感度78.12%、特异度82.35%、准确率79.6%。

核心结论

  • 基于3T MRI单指数与双指数DWI的全病灶ADC直方图分析有助于鉴别肺癌与良性肺病变,D10th鉴别效能较稳健。

研究设计与样本

  • 由两名放射科医师独立计算单指数ADC与双指数D的全病灶直方图参数(均值、10th与90th百分位、峰度、偏度),并以ROC曲线评价诊断效能。

关键影像表现/征象

  • 肺癌ADC均值、ADC10th、D均值、D10th显著低于良性病变(p<0.05)。
  • 肺癌ADC偏度与D偏度显著高于良性病变(p<0.05)。

诊断标准与关键数值

  • D10th以0.453×10⁻³ mm/s为最佳阈值鉴别肺癌与良性病变,敏感度78.12%、特异度82.35%、准确率79.6%。

临床应用与阅片要点

  • 阅片时可对病灶全容积勾画后行ADC与D直方图分析,重点关注D10th等低百分位参数辅助鉴别。
  • 肺癌ADC均值、ADC10th、D均值、D10th偏低而偏度偏高,可作为报告中的量化参考。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate whether whole-lesion histogram analysis of apparent diffusion coefficient (ADC) values derived from mono-exponential and bi-exponential diffusion-weighted imaging (DWI) can differentiate lung cancer from benign pulmonary lesions.

MATERIALS AND METHODS: Thirty-two patients with lung cancer and 17 patients with benign pulmonary lesions were included retrospectively. All patients underwent DWI before surgery or biopsy. ADC histogram parameters, including mean, percentile values (10th and 90th), kurtosis, and skewness, were calculated independently by two radiologists. The histogram parameters were compared between patients with lung cancer and benign lesions. Receiver operating characteristic curves were constructed to evaluate the diagnostic performance.

RESULTS: The ADCMean, ADC10th, DMean, D10th were significantly lower in lung cancer (1.187 ± 0.144 × 10-3; 0.440 ± 0.062 × 10-3; 1.068 ± 0.108 × 10-3; and 0.422 ± 0.049 × 10-3 mm/s) compared to benign lesions (1.418 ± 0.274 × 10-3; 0.555 ± 0.113 × 10-3; 1.216 ± 0.149 × 10-3; and 0.490 ± 0.044 × 10-3 mm/s; p<0.05). The ADCSkewness and DSkewness were significantly different between lung cancer (2.35 ± 0.72; 2.58 ± 1.14) and benign lesions (1.85 ± 0.54; 1.59 ± 1.47; p<0.05). D10th was robust in differentiating lung cancer from benign lesions. Using 0.453 × 10-3 mm/s as the optimal threshold, the sensitivity, specificity, and accuracy of D10th were 78.12%, 82.35%, and 79.6%, respectively.

CONCLUSION: Whole-lesion histogram analysis of ADC values derived by mono-exponential and bi-exponential DWI using 3 T magnetic resonance imaging helps distinguish lung cancer from benign pulmonary lesions.