CT引导下经皮穿刺肺活检学习曲线:17名胸科影像研究员回顾性评估
本研究回顾性分析17名胸科影像研究员完成的3261例CT引导下经皮穿刺肺活检,采用累积和法评估学习曲线。结果显示,达到可接受的诊断准确率需至少37例操作,假阴性率需52例,气胸和咯血并发症率并非所有操作者均达标。
要点
- 诊断准确率达标需约37例操作,假阴性率达标需52例。
- 气胸发生率32.6%,咯血2.7%,风险调整后部分操作者未达可接受气胸率。
- 学习曲线因操作者而异,需个体化评估培训与督导。
局限性
- 回顾性研究设计
- 单中心研究
- 仅纳入胸科影像研究员,可能限制普适性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. CT-guided percutaneous transthoracic needle biopsy (PTNB) is widely used for evaluation of indeterminate pulmonary lesions, although guidelines are lacking regarding the experience needed to gain sufficient skill. OBJECTIVE. The purpose of our study was to investigate the learning curve among a large number of operators in a tertiary referral hospital and to determine the number of procedures required to obtain acceptable performance. METHODS. This retrospective study included CT-guided PTNBs with coaxial technique performed by 17 thoracic imaging fellows from March 2, 2011, to August 8, 2017, who were novices in the procedure. A maximum number of 200 consecutive procedures per operator were included. The cumulative summation method was used to assess learning curves for diagnostic accuracy, false-negative rate, pneumothorax rate, and hemoptysis rate. Operators were assessed individually and in a pooled analysis. Pneumothorax risk was also assessed in a model adjusting for risk factors. Acceptable failure rates were defined as 0.1 for diagnostic accuracy and false-negative rate, 0.45 for pneumothorax rate, and 0.05 for hemoptysis rate. RESULTS. The study included 3261 procedures in 3134 patients (1876 men, 1258 women; mean age, 67.7 ± 12.1 [SD] years). Overall diagnostic accuracy was 94.2% (2960/3141). All 17 operators achieved acceptable diagnostic accuracy (37 procedures required in the pooled analysis; median, 33 procedures required [range, 19-67 procedures required]). Overall false-negative rate was 7.6% (179/2370). All 17 operators achieved acceptable false-negative rate (52 procedures required in the pooled analysis; median, 33 procedures required [range, 19-95 procedures required]). Pneumothorax occurred in 32.6% of the procedures (1063/3261 procedures), and hemoptysis occurred in 2.7% of the procedures (89/3261 procedures). All 17 operators achieved acceptable pneumothorax rate (20 procedures required in the pooled analysis; median, 19 procedures required [range, 7-63 procedures required]). In the risk-adjusted model, 15 operators achieved acceptable pneumothorax rate (54 procedures required in the pooled analysis; median, 36 procedures required [range, 10-192 procedures required]). Sixteen operators achieved acceptable hemoptysis rate (67 procedures required in the pooled analysis; median, 55 procedures required [range, 41-152 procedures required]). CONCLUSION. For CT-guided PTNB, at least 37 and 52 procedures are required to achieve acceptable diagnostic accuracy and false-negative rate, respectively. Not all operators achieved acceptable complication rates. CLINICAL IMPACT. The findings may help set standards for training, supervision, and ongoing assessment of operator proficiency for this procedure.
引用
- Park R, Lee SM, Kim S, et al. Learning Curve for CT-Guided Percutaneous Transthoracic Needle Biopsy: Retrospective Evaluation Among 17 Thoracic Imaging Fellows at a Tertiary Referral Hospital. AJR Am J Roentgenol. 2021. PMID: 34406052. doi:10.2214/AJR.21.26346
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。