文献速递胸部儿科影像MR

高极化129氙MRI通气缺陷百分比量化:阈值法与线性分箱法在多种肺病中的比较

Hyperpolarized 129Xenon MRI Ventilation Defect Quantification via Thresholding and Linear Binning in Multiple Pulmonary Diseases.
PubMed 文献 · Acad Radiol · 2021-08-12

本研究在176例受试者(健康对照23例及多种肺病患者)中,比较5种高极化129Xe MRI通气缺陷百分比量化方法。结果显示,N4ITK偏场校正后60%阈值法在区分病变组与对照组时预测效能、敏感度和特异度最高(VDP切点2.3%),但线性分箱法能更好标记轻度梗阻患者的低通气区域。

要点

  • N4ITK偏场校正后60%阈值法在VDP切点2.3%时区分病变组与对照组效能最佳。
  • 线性分箱法能更好地标记轻度梗阻(如哮喘)患者的细微低通气区域。
  • 所有量化方法标记的通风缺陷区域视觉上相似,但不同疾病间VDP差异各异。

核心结论

  • 不同量化方法下健康对照与患者间的VDP差异随疾病状态而异,N4ITK偏场校正后60%阈值法在区分合并病变组与对照组时效能最高,而线性分箱法能更好标记低通气区域。

研究设计与样本

  • 单中心研究,共纳入176例受试者(125例儿童、51例成人,年龄20.98±16.48岁),包括健康对照23例及囊性纤维化37例、淋巴管肌瘤病29例、哮喘22例、全身型幼年特发性关节炎11例、间质性肺病7例、骨髓移植受者47例。
  • 采用3T Philips扫描仪行2D多层面梯度回波序列HP 129Xe通气MRI,屏气≤16秒,TR/TE 8.0/4.0ms,FA 10-12°,FOV 300×300mm,体素约3×3×15mm。
  • 比较5种VDP量化方法:线性偏场校正或N4ITK偏场校正后线性分箱(直方图归一化分6簇)、线性偏场校正后≤60%平均信号强度阈值法、N4ITK偏场校正后≤60%和≤75%阈值法;84%受试者成功获得肺功能检查。

关键影像表现/征象

  • 所有量化方案均能在所有受试者中标记视觉可识别的通气缺陷的相似区域。
  • 大多数量化方法下,对照组VDP显著低于骨髓移植、囊性纤维化、淋巴管肌瘤病和间质性肺病组(p<0.05)。
  • 没有一种量化方案能更好地区分单个疾病组与对照组。

诊断标准与关键数值

  • 在比较对照组与合并疾病组时,N4ITK偏场校正后60%阈值法在VDP切点2.3%处具有最高的预测效能、敏感度和特异度(原文未报告具体数值)。

临床应用与阅片要点

  • 日常阅片和报告中需注意VDP量化方法的选择会影响健康对照与患者间的差异比较,不同疾病状态可能适用不同方法。
  • 对于轻度梗阻患者(如哮喘),线性分箱法可能比60%阈值法更能显示细微低通气区域,避免遗漏。

局限性

  • 原文未明确报告研究局限性;本研究为单中心设计,样本中部分疾病组样本量较小(如间质性肺病7例、全身型幼年特发性关节炎11例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE: There is no agreed upon method for quantifying ventilation defect percentage (VDP) with high sensitivity and specificity from hyperpolarized (HP) gas ventilation MR images in multiple pulmonary diseases for both pediatrics and adults, yet identifying such methods will be necessary for future multi-site trials. Most HP gas MRI ventilation research focuses on a specific pulmonary disease and utilizes one quantification scheme for determining VDP. Here we sought to determine the potential of different methods for quantifying VDP from HP 129Xe images in multiple pulmonary diseases through comparison of the most utilized quantification schemes: linear binning and thresholding.

MATERIALS AND METHODS: HP 129Xe MRI was performed in a total of 176 subjects (125 pediatrics and 51 adults, age 20.98±16.48 years) who were either healthy controls (n = 23) or clinically diagnosed with cystic fibrosis (CF) (n = 37), lymphangioleiomyomatosis (LAM) (n = 29), asthma (n = 22), systemic juvenile idiopathic arthritis (sJIA) (n = 11), interstitial lung disease (ILD) (n = 7), or were bone marrow transplant (BMT) recipients (n = 47). HP 129Xe ventilation images were acquired during a ≤16 second breath-hold using a 2D multi-slice gradient echo sequence on a 3T Philips scanner (TR/TE 8.0/4.0ms, FA 10-12°, FOV 300 × 300mm, voxel size≈3 × 3 × 15mm). Images were analyzed using 5 different methods to quantify VDPs: linear binning (histogram normalization with binning into 6 clusters) following either linear or a variant of a nonparametric nonuniform intensity normalization algorithm (N4ITK) bias-field correction, thresholding ≤60% of the mean signal intensity with linear bias-field correction, and thresholding ≤60% and ≤75% of the mean signal intensity following N4ITK bias-field correction. Spirometry was successfully obtained in 84% of subjects.

RESULTS: All quantification schemes were able to label visually identifiable ventilation defects in similar regions within all subjects. The VDPs of control subjects were significantly lower (p<0.05) compared to BMT, CF, LAM, and ILD subjects for most of the quantification methods. No one quantification scheme was better able to differentiate individual disease groups from the control group. Advanced statistical modeling of the VDP quantification schemes revealed that in comparing controls to the combined disease group, N4ITK bias-field corrected 60% thresholding had the highest predictive efficacy, sensitivity, and specificity at the VDP cut-point of 2.3%. However, compared to the thresholding quantification schemes, linear binning was able to capture and label subtle low-ventilation regions in subjects with milder obstruction, such as subjects with asthma.

CONCLUSION: The difference in VDP between healthy controls and patients varied between the different disease states for all quantification methods. Although N4ITK bias-field corrected 60% thresholding was superior in separating the combined diseased group from controls, linear binning is able to better label low-ventilation regions unlike the current, 60% thresholding scheme. For future clinical trials, a consensus will need to be reached on which VDP scheme to utilize, as there are subtle advantages for each for specific disease.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Roach DJ, Willmering MM, Plummer JW, et al. Hyperpolarized 129Xenon MRI Ventilation Defect Quantification via Thresholding and Linear Binning in Multiple Pulmonary Diseases. Acad Radiol. 2021. PMID: 34393064. doi:10.1016/j.acra.2021.06.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。