双能CT鉴别鼻腔鼻窦良性与恶性病变:与模拟单能CT、常规MRI及DWI的比较
研究纳入经组织病理学证实的鼻腔鼻窦病变患者38例良性、34例恶性,均行双能CT、常规MRI及DWI。双能CT定量参数联合形态学特征鉴别良恶性的AUC为0.935、敏感度96.67%、特异度90.00%、准确率93.52%,其AUC高于模拟单能CT、常规MRI、DWI及常规MRI+DWI。作者认为双能CT似乎是更准确的鉴别手段。
要点
- 双能CT定量参数联合形态学特征鉴别鼻腔鼻窦良恶性病变AUC为0.935。
- 恶性病变的碘浓度、有效原子序数、40/60/80 keV、斜率k、Mix-0.3均高于良性病变。
核心结论
- 与模拟单能CT、常规MRI及DWI相比,双能CT似乎是鉴别鼻腔鼻窦良恶性病变更准确的影像技术。
研究设计与样本
- 经组织病理学证实的鼻腔鼻窦病变患者38例良性、34例恶性,行双能CT、常规MRI及DWI;比较双能CT衍生参数、双能CT形态学特征、常规MRI特征及ADC值,采用ROC曲线评估诊断效能,Z检验比较AUC。
关键影像表现/征象
- 双能CT衍生单参数碘浓度、有效原子序数、40 keV、60 keV、80 keV、斜率k、Mix-0.3在恶性病变中显著高于良性鼻腔鼻窦病变(均P<0.004,Bonferroni校正)。
- 双能CT定量参数联合形态学特征鉴别良恶性的AUC为0.935、敏感度96.67%、特异度90.00%、准确率93.52%。
诊断标准与关键数值
- 双能CT定量参数联合形态学特征鉴别良恶性鼻腔鼻窦病变的AUC为0.935、敏感度96.67%、特异度90.00%、准确率93.52%。
- 双能CT的AUC高于Mix-0.3(模拟单能CT)、常规MRI、DWI及常规MRI+DWI。
- 双能CT定量参数(碘浓度、有效原子序数、40 keV、60 keV、80 keV、斜率k)联合可提高鉴别两类病变的诊断效能。
临床应用与阅片要点
- 作者认为双能CT似乎是鉴别鼻腔鼻窦良恶性病变更准确的影像技术,其AUC高于模拟单能CT、常规MRI、DWI及常规MRI+DWI。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore the value of dual-energy CT (DECT) for differentiating benign sinonasal lesions from malignant ones, and to compare this finding with simulated single-energy CT (SECT), conventional MRI (cMRI), and diffusion-weighted imaging (DWI).
METHODS: Patients with sinonasal lesions (38 benign and 34 malignant) who were confirmed by histopathology underwent DECT, cMRI, and DWI. DECT-derived parameters (iodine concentration (IC), effective atomic number (Eff-Z), 40-180 keV (20-keV interval), virtual non-enhancement (VNC), slope (k), and linear-mixed 0.3 (Mix-0.3)), DECT morphological features, cMRI characteristics, and ADC value of benign and malignant tumors were compared using t test or chi-square test. Receiver operating characteristic (ROC) curve was performed to evaluate the diagnostic performance, and the area under the ROC curve (AUC) was compared using the Z test to select the optimal diagnostic approach.
RESULTS: Significantly higher DECT-derived single parameters (IC, Eff-Z, 40 keV, 60 keV, 80 keV, slope (k), Mix-0.3) were found in malignant lesions than those of benign sinonasal lesions (all p < 0.004, Bonferroni correction). Combined quantitative parameters (IC, Eff-Z, 40 keV, 60 keV, 80 keV, slope (k)) can improve the diagnostic efficiency for discriminating these two entities. Combination of DECT quantitative parameters and morphological features can further improve the overall diagnostic performance, with AUC, sensitivity, specificity, and accuracy of 0.935, 96.67%, 90.00%, and 93.52%. Moreover, the AUC of DECT was higher than those of Mix-0.3 (simulated SECT), cMRI, DWI, and cMRI+DWI.
CONCLUSIONS: Compared with simulated SECT, cMRI, and DWI, DECT appears to be a more accurate imaging technique for differentiating benign from malignant sinonasal lesions.
KEY POINTS: • DE can differentiate benign sinonasal lesions from malignant ones based on DECT-derived qualitative parameters. • DECT appears to be more accurate in the diagnosis of sinonasal lesions when compared with simulated SECT, cMRI, and DWI.
引用
- Wang P, Tang Z, Xiao Z, et al. Dual-energy CT in differentiating benign sinonasal lesions from malignant ones: comparison with simulated single-energy CT, conventional MRI, and DWI. Eur Radiol. 2021. PMID: 34427744. doi:10.1007/s00330-021-08159-3