双能CTA虚拟平扫评估大血管闭塞性急性缺血性卒中ASPECTS:重复CT的剂量降低机会
回顾性分析51例大血管闭塞急性缺血性卒中患者,比较双能CTA虚拟平扫(DECTA-VNC)与非增强CT(NCCT)的ASPECTS评分。DECTA-VNC与NCCT的ASPECTS评分差异≤1分的患者比例达96%(读者1)和90%(读者2),且辐射剂量显著更低(CTDIvol 20.9 vs 63.7 mGy,p<0.0001)。结论认为DECTA-VNC在检测早期缺血性低密度水肿/梗死方面不劣于NCCT。
要点
- DECTA-VNC与NCCT的ASPECTS评分高度一致,可作为替代以减少辐射剂量。
- DECTA-VNC的ASPECTS观察者间一致性最高(κ=0.71),优于NCCT(κ=0.40)。
- DECTA-VNC的CTDIvol和DLP均显著低于NCCT(p<0.0001)。
关键影像表现/征象
- DECTA-VNC与共识NCCT的ASPECTS评分差异≤1分的患者比例:读者1为49/51(96%),读者2为46/51(90%)。
- DECTA-SI与共识NCCT的ASPECTS评分差异≤1分的患者比例:两名读者均为45/51(88%)。
- ASPECTS观察者间一致性:DECTA-VNC κ=0.71,DECTA-SI κ=0.48,NCCT κ=0.40。
诊断标准与关键数值
- 以ASPECTS区域为单位,DECTA-VNC的敏感度87%、特异度95%、PPV 0.82%、NPV 0.96%。
临床应用与阅片要点
- 在LVO-AIS患者中,可利用DECTA-VNC替代NCCT进行ASPECTS评分,减少重复CT的辐射剂量。
- DECTA-VNC的观察者间一致性较高,可能有助于提高ASPECTS评分的可重复性。
局限性
- 回顾性研究,样本量较小(51例),单中心设计。
- 原文未报告其他明显局限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Recent studies have shown the feasibility of dual-energy CT (DECT) virtual non-contrast (VNC) for determining infarct extent. In this study, patients presenting with large-vessel occlusion (LVO) acute ischemic stroke (AIS), we assess whether ASPECTS on DECTA-VNC differs from non-contrast CT (NCCT).
METHODS: After IRB approval, LVO-AIS patients undergoing NCCT and DECTA between October 2016 and September 2018 were retrospectively reviewed. DECTA-VNC images were derived using Syngo.via (Siemens, Erlangen, Germany). ASPECTS was scored by two blinded neuroradiologists. Square-weighted kappa statistic, diagnostic performance, Wilcoxon signed-rank tests between groups, and CT doses were calculated.
RESULTS: Fifty-one patients met inclusion criteria, with median age of 76 (IQR 67-82); 26/51 (51%) were female. Median time between last-known-well and CT was 120 min (IQR 60-252). DECTA-VNC ASPECTS score differed by ≤ 1 from consensus NCCT in 49/51 (96%) patients for reader 1 and in 46/51 (90%) for reader 2. ASPECTS on DECTA-SI and consensus NCCT differed by ≤ 1 in 45/51 (88%) for both readers. On a per ASPECTS-region basis, DECTA-VNC had 87% sensitivity, 95% specificity, 0.82% PPV, and 0.96% NPV. ASPECTS inter-rater agreement was highest for DECTA-VNC (κ = 0.71), DECTA-SI (κ = 0.48), and NCCT (κ = 0.40). NCCT median CTDIvol was 63.7 mGy (IQR 60.7-67.2); DLP was 1060.0 mGy·cm (IQR 981.0-1151.5). DECTA-VNC dose was lower: median CTDIvol was 20.9 mGy (IQR 19.8-22.2); DLP was 804.1 (IQR 691.6-869.4), p < 0.0001.
CONCLUSION: DECTA-derived VNC yielded similar ASPECTS scores as NCCT and is therefore non-inferior in early ischemia-related low attenuation edema/infarct detection in acute LVO-AIS patients. Further evaluation of the role of DECTA-VNC in AIS imaging is warranted.
引用
- van den Broek M, Byrne D, Lyndon D, et al. ASPECTS estimation using dual-energy CTA-derived virtual non-contrast in large vessel occlusion acute ischemic stroke: a dose reduction opportunity for patients undergoing repeat CT? Neuroradiology. 2021. PMID: 34379143. doi:10.1007/s00234-021-02773-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。