文献速递神经CTMR

急性缺血性卒中脑灌注图像处理软件的真实世界双向比较

Two-way comparison of brain perfusion image processing software for patients with acute ischemic strokes in real-world.
PubMed 文献 · Neuroradiology · 2021-07-31

本研究纳入符合MR CLEAN试验标准的611例急性缺血性卒中患者,分别用imSTROKE与RAPID软件估算缺血核心和半暗带体积,采用Bland-Altman和ICC评估一致性。结果显示两软件在核心和半暗带体积估算上高度一致(ICC均约0.988),对于小核心体积患者imSTROKE可能灵敏度更优。

要点

  • imSTROKE与RAPID估算核心和半暗带体积高度一致,可互参考。
  • 小核心体积患者中imSTROKE可能较RAPID灵敏度更优。
  • 两软件在特定阈值下准确性经检验,但具体数值未在摘要报告。

局限性

  • 真实世界研究设计可能存在选择偏倚。
  • 摘要未报告准确性检验的具体数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Perfusion imaging generates multimaps of ischemic tissues and is a proven decision-making tool in patients with acute ischemic stroke. However, the reliability of perfusion post-processing outcomes has been debated, given disparate results of various software applications, especially for patients with small ischemic core volume. This study was undertaken to compare ischemic volume estimates determined by imSTROKE (a software with new imaging protocol) and RAPID computer applications, respectively.

METHODS: A total of 611 patients qualified for study, each having met inclusion and exclusion criteria of the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN trial). Subjects were examined by computed tomography perfusion (CTP) imaging (n = 349) or perfusion-weighted (PWI) and diffusion-weighted (DWI) imaging (n = 262). Ischemic volumes estimated by imSTROKE and RAPID applications were then compared. We used Bland-Altman analysis and intraclass correlation coefficients (ICCs) to ascertain agreement between applications. Accuracies of estimated core infarct and penumbra volumes were tested at specific thresholds (core: 25 mL, 50 mL, and 70 mL; penumbra: 45 mL, 90 mL, and 125 mL).

RESULTS: Median core infarct volumes by imSTROKE and RAPID were 29.18 mL and 29.53 mL, respectively (ICC = 0.9880, 95% confidence interval [CI]: 0.9860-0.9898). Median penumbra volumes by imSTROKE and RAPID were 68.20 mL and 68.55 mL, respectively (ICC = 0.9885, 95% CI: 0.9865-0.9902).

CONCLUSION: In estimating core infarct and penumbra volumes, imSTROKE and RAPID applications showed high-level agreement. For patients with small ischemic core volume, compared with RAPID, imSTROKE may have better sensitivity.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Cai H, Fan S, Bian Y, et al. Two-way comparison of brain perfusion image processing software for patients with acute ischemic strokes in real-world. Neuroradiology. 2021. PMID: 34331546. doi:10.1007/s00234-021-02771-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。