文献速递神经外周血管MR

基于深度学习的软件提高临床医生对脑TOF-MRA动脉瘤的检测敏感性

Deep Learning-Based Software Improves Clinicians' Detection Sensitivity of Aneurysms on Brain TOF-MRA.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-08-12

本研究回顾性纳入332例颅内动脉瘤患者的TOF-MRA,由2名放射科医生、1名神经外科医生和1名神经内科医生盲法判读,洗脱期后借助深度学习软件再次判读。软件辅助后基于患者的敏感性从73.5%提高至86.5%(P < .001),神经外科医生和神经内科医生敏感性显著提高,假阳性未显著增加;对放射科医生价值不明确。

要点

  • 软件辅助使基于患者的敏感性从73.5%提高至86.5%(P < .001)。
  • 神经外科医生敏感性从74.8%提高至85.2%(P = .03),神经内科医生从56.3%提高至84.4%(P < .001)。
  • 神经外科医生假阳性从23例增至30例(P = .20),神经内科医生从22例增至24例(P = .75),均无显著增加。

核心结论

  • 软件辅助判读可显著提高临床医生检测MRA动脉瘤的敏感性,且不显著增加假阳性,对神经外科医生和神经内科医生尤为明显;对放射科医生价值不明确。

研究设计与样本

  • 回顾性提取颅内动脉瘤的TOF-MRA检查,共332例患者,由2名放射科医生、1名神经外科医生和1名神经内科医生盲法判读,洗脱期后借助深度学习软件再次判读;采用广义估计方程的逻辑回归比较诊断性能。

诊断标准与关键数值

  • 基于患者的敏感性:无软件辅助73.5% vs 软件辅助86.5%,P < .001。
  • 神经外科医生基于患者的敏感性:无软件辅助74.8% vs 软件辅助85.2%,P = .03。
  • 神经内科医生基于患者的敏感性:无软件辅助56.3% vs 软件辅助84.4%,P < .001。
  • 神经外科医生假阳性病例数:无软件辅助23例 vs 软件辅助30例,P = .20。
  • 神经内科医生假阳性病例数:无软件辅助22例 vs 软件辅助24例,P = .75。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The detection of cerebral aneurysms on MRA is a challenging task. Recent studies have used deep learning-based software for automated detection of aneurysms on MRA and have reported high performance. The purpose of this study was to evaluate the incremental value of using deep learning-based software for the detection of aneurysms on MRA by 2 radiologists, a neurosurgeon, and a neurologist.

MATERIALS AND METHODS: TOF-MRA examinations of intracranial aneurysms were retrospectively extracted. Four physicians interpreted the MRA blindly. After a washout period, they interpreted MRA again using the software. Sensitivity and specificity per patient, sensitivity per lesion, and the number of false-positives per case were measured. Diagnostic performances, including subgroup analysis of lesions, were compared. Logistic regression with a generalized estimating equation was used.

RESULTS: A total of 332 patients were evaluated; 135 patients had positive findings with 169 lesions. With software assistance, patient-based sensitivity was statistically improved after the washout period (73.5% versus 86.5%, P < .001). The neurosurgeon and neurologist showed a significant increase in patient-based sensitivity with software assistance (74.8% versus 85.2%, P = .03, and 56.3% versus 84.4%, P < .001, respectively), while the number of false-positive cases did not increase significantly (23 versus 30, P = .20, and 22 versus 24, P = .75, respectively).

CONCLUSIONS: Software-aided reading showed significant incremental value in the sensitivity of clinicians in the detection of aneurysms on MRA without a significant increase in false-positive findings, especially for the neurosurgeon and neurologist. Software-aided reading showed equivocal value for the radiologist.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Sohn B, Park KY, Choi J, et al. Deep Learning-Based Software Improves Clinicians' Detection Sensitivity of Aneurysms on Brain TOF-MRA. AJNR Am J Neuroradiol. 2021. PMID: 34385143. doi:10.3174/ajnr.A7242

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。