增加冠状位DWI在卒中影像中的价值:准确性与实用性
本研究回顾性比较轴位与冠状位DWI(层厚4或5 mm,间隔1 mm)对亚厘米梗死的检出能力,两轮阅片显示联合双平面可将敏感度从88.9%提升至98.1%(p=0.03),特异度提升未达统计学显著性,假阴性与假阳性病灶的rCNR和rROI较低。
要点
- 联合轴位与冠状位DWI可提高小梗死检出敏感度,尤其对 subtle 病灶。
- 假阴性及假阳性病灶的rCNR和rROI较低,提示对比度不足易致误判。
- 即使不采用薄层扫描,增加第二成像平面仍有助减少单平面漏诊。
核心结论
- 在卒中方案中同时纳入层厚相同的轴位与冠状位DWI可改善小梗死检出,单平面易误诊。
研究设计与样本
- 回顾性研究,两轮数据采集,两名放射科医师参与,以专家复核确定真性梗死与伪影。
- DWI层厚4或5 mm,层间隔1 mm,比较单独轴位、单独冠状位及轴位联合冠状位阅片。
关键影像表现/征象
- 假阴性和假阳性病灶的rCNR与rROI值均较低。
诊断标准与关键数值
- 第一轮:轴位检出敏感度92.7%和100%,冠状位95.1%和92.7%(两名医师分别)。
- 第二轮:联合轴位与冠状位后两名医师敏感度均从88.9%提升至98.1%(p=0.03)。
- 特异度提升未达统计学显著性(p=0.06和0.12)。
临床应用与阅片要点
- 阅片时建议同时观察轴位与冠状位DWI,对皮层下或脑干等小病灶区域尤其注意。
- 发现低rCNR可疑病灶时应结合双平面确认,减少假阳性与假阴性报告。
局限性
- 回顾性设计,仅两名放射科医师参与,样本量未在摘要中报告。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the value of adding additional coronal diffusion-weighted imaging with the same section thickness as standard axial images to improve detection of small infarcts.
MATERIALS AND METHODS: Axial and coronal diffusion-weighted images (4 or 5 mm section thickness, 1 mm gap) were studied retrospectively in two rounds of data collection. During the first round, two radiologists identified sub-centimetre infarcts on only axial images during one sitting, and only coronal images during a second sitting. During the second round, the two radiologists were asked to identify infarcts on only axial images during one sitting, and on both axial and coronal images simultaneously during the second sitting. An expert reviewer determined true infarcts and artefacts. Relative contrast-to-noise ratios (rCNR) and relative mean region of interest (rROI) within each lesion were calculated.
RESULTS: During the first round, sensitivity for infarct detection for the two radiologists was 92.7% and 100% on axial and 95.1% and 92.7% on coronal, respectively. During the second round, sensitivity improved from 88.9% to 98.1% for both radiologists (p=0.03). Specificity improved but did not reach statistical significance (p=0.06 and 0.12). False-negative and false-positive lesions had lower rCNR and rROI values.
CONCLUSION: Including both axial and coronal DWI images with the same section thickness in the stroke protocol improves detection of small infarcts, which can be misdiagnosed on a single imaging plane. A second imaging plane is particularly useful for subtle infarcts, even without acquiring thin-section images.
引用
- Baggett M, Helmy D, Chang J, et al. Added value in stroke imaging: accuracy and utility of additional coronal diffusion-weighted imaging. Clin Radiol. 2021. PMID: 34384563. doi:10.1016/j.crad.2021.07.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。