多模态CT卒中方案中对比剂团注对CTP的干扰
该回顾性研究分析1980例卒中患者,比较CTP在CTA前(368例)或后(1612例)进行对灌注参数的影响。两组平均基线HU有差异(41 vs 45 HU),但灌注指标、低灌注体积及核心梗死体积无显著差异。49例患者CTA团注下降支干扰CTP基线导致CBV假性降低,校正方法可消除此误差。
要点
- CTP在CTA后执行时,建议等待约30秒或应用校正方法,避免CBV假性降低导致核心梗死高估。
- CTA后CTP的灌注指标、低灌注体积及核心梗死体积与CTA前CTP无显著差异,整体可靠。
- CTA团注下降支可能干扰CTP基线,造成CBV值错误降低,需注意识别。
关键影像表现/征象
- A组与B组CTP平均基线值分别为41 HU和45 HU,差异显著。
- 49例患者CTA团注下降支干扰CTP基线,导致CBV值错误降低。
- 应用校正方法后上述CBV错误消失。
诊断标准与关键数值
- CTP在CTA后执行时,建议观察约30秒的短暂停或应用适当校正方法。
- 两组灌注指标、低灌注体积及核心梗死体积无显著差异。
临床应用与阅片要点
- CTA后行CTP时,注意团注下降支对基线的干扰,避免CBV假性降低误判为核心梗死。
- 可常规等待约30秒或采用校正方法,减少因核心梗死高估而排除机械取栓患者。
局限性
- 回顾性研究设计。
- 单中心研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Whether CTP is performed before or after CTA varies within multimodal CT stroke protocols. CTA after CTP might show venous filling, and CTP metrics might be disturbed by prior CTA. Therefore, we compared CTP metrics conducted before and after CTA in a large cohort of patients with stroke and analyzed interferences of the CTA bolus with the CTP measurement.
MATERIALS AND METHODS: We analyzed 1980 patients (368 patients with CTP performed before CTA [group A] versus 1612 patients with CTP performed after [group B]) in a retrospective study. Mean curves, histograms of CTP baseline Hounsfield units, CBF, CBV, time-to-maximum, hypoperfusion, and core volumes were calculated using the software VEOcore. CTA and CTP interferences were analyzed, and a detection and correction method was proposed.
RESULTS: Mean CTP baseline values were significantly different in both groups (41 versus 45 HU within the groups A and B, respectively). However, perfusion metrics, hypoperfusion, and core volumes yielded no significant differences. In 49 patients, the descending flank of the CTA bolus interfered with the baseline of the CTP measurement, leading to erroneously low CBV values. These errors vanished when a correction method was applied.
CONCLUSIONS: CTP can be reliably performed after CTA without a relevant net effect on perfusion metrics. However, when measuring CTP after CTA, either a short pause on the order of 30 seconds should be observed or an appropriate correction method should be applied. It may help to avoid excluding patients from mechanical thrombectomy by overestimating infarct cores.
引用
- Kellner E, Rau A, Demerath T, et al. Contrast Bolus Interference in a Multimodal CT Stroke Protocol. AJNR Am J Neuroradiol. 2021. PMID: 34413063. doi:10.3174/ajnr.A7247
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。