文献速递妇产影像神经儿科影像MR

胎儿脑结构MRI参考范围研究的方法学系统评价

Reference ranges for fetal brain structures using magnetic resonance imaging: systematic review.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-02-10

总体平均质量评分为48.7%,研究设计域42.0%,统计与报告方法域59.4%,MRI相关特殊方面域33.3%。结论认为多数已发表研究异质性高、方法学质量低至中等。

要点

  • 胎儿脑MRI参考范围研究总体方法学质量偏低,平均评分仅48.7%。
  • MRI相关特殊方面域评分最低(33.3%),无研究完成全胎儿脑评估。
  • 研究设计域中样本量计算和连续入组是偏倚风险最高的项目。

核心结论

  • 多数已发表的胎儿脑MRI参考范围研究异质性高,方法学质量低至中等,与超声研究的类似发现一致。

研究设计与样本

  • 采用26项质量标准分三域(研究设计、统计与报告方法、MRI相关特殊方面)评估方法学适当性,总分0–26分并以百分比表示,百分比越低偏倚风险越高。

诊断标准与关键数值

  • 总体平均质量评分为48.7%,研究设计域42.0%,统计与报告方法域59.4%,MRI相关特殊方面域33.3%。
  • 研究设计域中样本量计算和连续入组妇女为偏倚风险最高项目。
  • 统计与报告方法域中每个测量均值与标准差的回归方程、每个变量的测量次数及产后评估信息为偏倚风险最高项目。
  • MRI相关特殊方面域中全胎儿脑评估未在任何纳入研究中完成,为偏倚风险最高项目。

临床应用与阅片要点

  • 阅片或引用胎儿脑MRI参考范围时,需注意原研究方法学质量偏低、异质性高,参考值外推应谨慎。
  • 关注研究是否报告样本量计算、连续入组、回归方程及测量次数等质量条目,以判断参考范围的可靠性。

局限性

  • 评估基于研究报道内容,可能存在发表偏倚或报告不完整的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the methodology of studies reporting reference ranges for fetal brain structures on magnetic resonance imaging (MRI).

METHODS: MEDLINE, EMBASE, CINAHL and the Web of Science databases were searched electronically up to 31 December 2020 to identify studies investigating biometry and growth of the fetal brain and reporting reference ranges for brain structures using MRI. The primary aim was to evaluate the methodology of these studies. A list of 26 quality criteria divided into three domains, including 'study design', 'statistical and reporting methods' and 'specific aspects relevant to MRI', was developed and applied to evaluate the methodological appropriateness of each of the included studies. The overall quality score of a study, ranging between 0 and 26, was defined as the sum of scores awarded for each quality criterion and expressed as a percentage (the lower the percentage, the higher the risk of bias).

RESULTS: Fifteen studies were included in this systematic review. The overall mean quality score of the studies evaluated was 48.7%. When focusing on each domain, the mean quality score was 42.0% for 'study design', 59.4% for 'statistical and reporting methods' and 33.3% for 'specific aspects relevant to MRI'. For the 'study design' domain, sample size calculation and consecutive enrolment of women were the items found to be at the highest risk of bias. For the 'statistical and reporting methods' domain, the presence of regression equations for mean and SD for each measurement, the number of measurements taken for each variable and the presence of postnatal assessment information were the items found to be at the highest risk of bias. For the 'specific aspects relevant to MRI' domain, whole fetal brain assessment was not performed in any of the included studies and was therefore considered to be the item at the highest risk of bias.

CONCLUSIONS: Most of the previously published studies reporting fetal brain reference ranges on MRI are highly heterogeneous and have low-to-moderate quality in terms of methodology, which is similar to the findings reported for ultrasound studies. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Di Mascio D, Khalil A, Rizzo G, et al. Reference ranges for fetal brain structures using magnetic resonance imaging: systematic review. Ultrasound Obstet Gynecol. 2022. PMID: 34405927. doi:10.1002/uog.23762

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。