经桡动脉双球囊保护系统用于锁骨下动脉支架置入:球囊切换技术及文献回顾
本文报道1例79岁女性因左锁骨下动脉近端重度狭窄致左锁骨下动脉窃血综合征,采用经左桡动脉无鞘途径的双球囊保护系统(球囊切换技术)行支架置入。术中在椎动脉开口水平充盈8F球囊导引导管保护椎动脉,支架置入并减压后冲洗滞留的椎动脉血流,再充盈球囊导引导管后撤出支架输送系统并抽吸血栓碎屑。术后造影示血运重建成功,神经影像未见缺血性卒中。
要点
- 左锁骨下动脉近端病变支架置入时,椎动脉开口水平的球囊导引导管可提供椎动脉栓塞保护。
- 球囊切换技术的关键步骤是支架释放后先减压支架球囊、冲洗滞留的椎动脉血流,再充盈球囊导引导管撤出输送系统。
- 撤出支架输送系统前应充分抽吸球囊导引导管近端的漂浮碎屑,以降低后循环栓塞风险。
核心结论
- 经桡动脉双球囊保护系统(球囊切换技术)可降低左锁骨下动脉支架置入过程中椎动脉栓塞的风险,是左锁骨下动脉闭塞性疾病的有用治疗选择。
研究设计与样本
- 本文为个案报道并附文献回顾,报道1例79岁女性左锁骨下动脉近端重度狭窄患者,采用经左桡动脉无鞘途径行球囊切换技术支架置入,术后行血管造影及神经影像评估。
关键影像表现/征象
- 左锁骨下动脉造影示支架置入后血运重建成功。
- 术后神经影像未见缺血性卒中证据。
- 术中球囊导引导管充盈后可见左椎动脉血流滞留,减压后滞留血流被冲向左锁骨下动脉远端。
临床应用与阅片要点
- 对左锁骨下动脉近端重度狭窄行支架置入时,可考虑在椎动脉开口水平充盈球囊导引导管以保护椎动脉。
- 操作中需注意支架释放后先减压支架球囊并冲洗滞留的椎动脉血流,再充盈球囊导引导管撤出输送系统。
- 撤出支架输送系统前应抽吸球囊导引导管近端漂浮碎屑,减少后循环栓塞。
局限性
- 本文为单个病例报道,样本量小,结论的外推需谨慎。
- 原文未报告长期随访、对照设计或并发症发生率等数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Endovascular treatment for subclavian artery (SA) occlusive disease is well established; however, a potential risk remains for posterior circulation embolism, which can be life threatening. To reduce the risk of vertebral artery (VA) embolism, we have devised a transradial dual-balloon protection system referred to as the balloon switching technique. Herein, we describe a patient with left SA stenosis who successfully underwent SA stenting using the balloon switching technique. Case presentation A 79-year-old woman with left arm claudication was diagnosed with left subclavian steal syndrome due to severe stenosis of the proximal left SA. Endovascular revascularization using the balloon switching technique was employed. To obtain VA embolic protection during device advancement through the SA lesion, an 8F balloon-guiding catheter was inflated in the left SA at the level of the VA takeoff using the left transradial sheathless approach. A balloon-expandable stent was inflated in the SA lesion, followed by deflation of the balloon-guiding catheter. The stagnant left VA flow was flushed away toward the distal left SA. Following reinflation of the balloon-guiding catheter, the stent delivery system was deflated and removed. Floating debris in the SA proximal to the balloon-guiding catheter was adequately aspirated, followed by deflation of the balloon-guiding catheter. Left SA angiography showed successful revascularization, and postprocedural neuroimaging showed no evidence of ischemic stroke.
CONCLUSIONS: The balloon switching technique reduces the risk of VA embolism during left SA stenting via the transradial access. This method is a useful therapeutic option for patients with left SA occlusive disease.
引用
- Yamazaki D, Hanaoka Y, Koyama JI, et al. Transradial dual-balloon protection system for subclavian artery stenting: "Balloon Switching" technique and literature review. Eur J Radiol. 2021. PMID: 34438329. doi:10.1016/j.ejrad.2021.109907
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。