体素内不相干运动微灌注MRI评估重症肢体缺血足部低灌注及预测PTA疗效
本研究纳入8例重症肢体缺血患者和6名健康志愿者,采用IVIM-MRI评估下肢微灌注,患者行PTA前后对比。结果显示PAD患者D*值低于健康人,成功PTA后D*值及ABI均显著升高,观察者间一致性良好(ICC=0.84)。IVIM-MRI可检测PAD与健康人的微灌注差异,并反映血运重建后的灌注改善。
要点
- IVIM-MRI可定量评估足部微循环灌注,D*值在PAD患者中低于健康人。
- 成功PTA后D*值和ABI均显著升高,提示微灌注改善。
- 观察者间一致性良好(ICC=0.84),支持IVIM-MRI的可重复性。
关键影像表现/征象
- PAD患者D*值低于健康志愿者(279.88 ± 13.47 vs 332.47 ± 22.95 10-5 mm2/s,p < 0.05)。
- 成功PTA后平均D*值从279.88 ± 13.47升高至331.51 ± 31 10-5 mm2/s(p < 0.05)。
- 成功PTA后平均踝臂指数从0.35 ± 0.2升高至0.76 ± 0.25(p < 0.05)。
诊断标准与关键数值
- IVIM-MRI微灌注参数D*:PAD患者PTA前均值279.88 ± 13.47 10-5 mm2/s,健康志愿者均值332.47 ± 22.95 10-5 mm2/s(p < 0.05)。
- PTA后D*均值331.51 ± 31 10-5 mm2/s(p < 0.05)。
- 观察者间一致性ICC = 0.84(95% CI 0.64-0.93)。
临床应用与阅片要点
- IVIM-MRI可作为评估PAD患者下肢微灌注的无创工具,辅助识别重症肢体缺血。
- PTA术后D*值升高可反映微灌注改善,可与ABI联合用于疗效评估。
- D*参数图需由两名观察者判读,一致性良好,适合临床重复测量。
局限性
- 样本量小(8例患者、6名健康志愿者),非多中心研究。
- 仅纳入接受PTA的患者,未与其他治疗方式或不同病因亚组比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To emerge hypoperfusion of lower limbs in patients with critical limb ischemia (CLI) using Intravoxel Incoherent Motion microperfusion magnetic resonance imaging (IVIM-MRI). Moreover to examine the ability of IVIM-MRI to differentiate patients with severe peripheral arterial disease (PAD) from normal subjects and evaluate the percutaneous transluminal angioplasty (PTA) results in patients with CLI.
METHODS: Eight patients who presented with CLI and six healthy volunteers were examined. The patients underwent IVIM-MRI of lower extremity before and following PTA. The imaging protocol included sagittal diffusion-weighted (DW) sequences. DW images were analyzed and color parametric maps of the micro-circulation of blood inside the capillary network (D*) were constructed. The studies were evaluated by two observers to define interobserver reproducibility.
RESULTS: Technical success was achieved in all patients (8/8). The mean ankle-brachial index increased from 0.35 ± 0.2 to 0.76 ± 0.25 (p < 0.05). Successful revascularization improved IVIM microperfusion. Mean D* increased from 279.88 ± 13.47 10-5 mm2/s to 331.51 ± 31 10-5 mm2/s, following PTA, p < 0.05. Moreover, PAD patients presented lower D* values as compared to healthy individuals (279.88 ± 13.47 10-5 mm2/s vs 332.47 ± 22.95 10-5 mm2/s, p < 0.05, respectively). Good interobserver agreement was obtained with an ICC = 0.84 (95% CI 0.64-0.93).
CONCLUSIONS: IVIM-MRI can detect differences in microperfusion between patients with PAD and healthy individuals. Moreover, significant restitution of IVIM microperfusion is found following successful PTA.
ADVANCES IN KNOWLEDGE: IVIM-MRI is a safe, reproducible and effective modality for evaluation of lower limb hypoperfusion in patients with PAD. It seems also to be a helpful tool to detect changes of tissue perfusion in patients with CLI following revascularization.
引用
- Galanakis N, Maris TG, Kalaitzakis G, et al. Evaluation of foot hypoperfusion and estimation of percutaneous transluminal angioplasty outcome in patients with critical limb ischemia using intravoxel incoherent motion microperfusion MRI. Br J Radiol. 2021. PMID: 34233490. doi:10.1259/bjr.20210215
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。