文献速递神经儿科影像介入CTDSA

脊髓性肌萎缩伴脊柱融合患儿鞘内导管及港座植入术

Intrathecal catheter and port placement for nusinersen infusion in children with spinal muscular atrophy and spinal fusion.
PubMed 文献 · Pediatr Radiol · 2021-07-12

结论认为该技术可在门诊给药,避免多次影像学操作,减少不适、费用及多次麻醉和辐射暴露的风险,但需进一步研究比较其与其他途径的风险获益。

要点

  • 完全后路脊柱融合患儿经皮影像引导鞘内港座植入技术可行,本组13例均成功。
  • 术后主要并发症为脑脊液漏和浅表感染,本组各1例导致港座移除。
  • 港座植入后可门诊输注诺西那生,避免反复经椎间孔腰椎穿刺及多次影像引导。

局限性

  • 样本量小(13例),为单中心回顾性研究。
  • 随访时间有限(至少23个月,部分仅1年)。
  • 未与其他给药途径(如反复经椎间孔腰椎穿刺)进行对照比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Spinal administration of medications is challenging in patients with complete posterior spinal fusion. We describe percutaneous image-guided intrathecal port placement for administration of the antisense oligonucleotide nusinersen for children and young adults with spinal muscular atrophy.

OBJECTIVE: To describe and present our initial experience with a new technique for administering nusinersen in patients with spinal muscular atrophy and posterior spinal fusion.

MATERIALS AND METHODS: We reviewed medical records of 13 patients who received intrathecal ports using DynaCT, biplane fluoroscopy and iGuide from April 2018 through June 2019, and we describe the clinical course over 1 year.

RESULTS: Image-guided catheter and port implantation was successful in all cases. Two ports were subsequently removed, one for persistent cerebrospinal fluid leak and one for superficial infection. The other 11 have functioned successfully for a minimum of 23 months.

CONCLUSION: We report our experience with image-guided intrathecal port placement in children with complete posterior spine fusion. The implanted port permits dosing in an outpatient setting and avoids the need for multiple future radiologic procedures, and it reduces discomfort, procedural costs and potential risks and sequelae of multiple anesthetics and radiation exposures. Further studies are needed to define the relative risks and benefits of intrathecal ports compared to other approaches such as repeated transforaminal lumbar punctures.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Shashi KK, Stone SSD, Berde CB, et al. Intrathecal catheter and port placement for nusinersen infusion in children with spinal muscular atrophy and spinal fusion. Pediatr Radiol. 2021. PMID: 34254153. doi:10.1007/s00247-021-05126-4