青少年股四头肌腱-髌骨自体移植物的MRI与人体测量预测

Prediction of quadriceps tendon-patellar bone autograft diameter in adolescents with 2-dimensional magnetic resonance imaging and anthropometric measures.
PubMed 文献 · Skeletal Radiol · 2021-07-22

本研究评估青少年股四头肌腱-髌骨自体移植物(QPA)尺寸与术前MRI测量及人体测量指标的相关性。纳入103例10-18岁ACL重建患者,发现移植物软组织端直径与髌骨上极上方20-40mm处股四头肌腱前后径测量相关(rs=0.51,p<0.001),但MRI测量显著低估实际移植物直径(9.6±0.8 vs 7.4±1.1,p<0.001)。骨端直径与髌骨上方10mm处测量无相关性,人体测量指标与移植物尺寸无关。

要点

  • 髌骨上极上方20-40mm处股四头肌腱前后径与移植物软组织端直径中度相关。
  • MRI测量显著低估移植物软组织端实际直径,报告中需谨慎解读。
  • 骨端移植物直径与髌骨上方10mm处测量无相关性,不宜用于预测。

关键影像表现/征象

  • 移植物软组织端直径与最靠近端的前后径测量显著相关(rs=0.51;p<0.001)。
  • MRI测量值显著低于实际软组织端移植物直径(9.6±0.8 vs. 7.4±1.1;p<0.001)。
  • 骨端移植物直径与髌骨上方10mm处前后径测量无相关性。

诊断标准与关键数值

  • 软组织端移植物直径与最靠近端前后径测量相关(rs=0.51;p<0.001)。
  • MRI测量低估软组织端直径:测量值7.4±1.1 vs. 实际9.6±0.8(p<0.001)。
  • 骨端移植物直径与髌骨上方10mm处前后径测量无相关性。

临床应用与阅片要点

  • 术前MRI测量髌骨上极上方20-40mm股四头肌腱前后径可辅助预测移植物软组织端尺寸。
  • 注意MRI测量会低估实际移植物直径,报告时避免过度自信。
  • 骨端尺寸不能通过髌骨上方10mm处测量预测,需结合其他信息。

局限性

  • 回顾性研究设计。
  • 骨骼成熟度与较小移植物尺寸相关(p=0.08),但未详细说明。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study evaluates the correlation between the bone end and soft tissue end of the quadriceps tendon-patellar bone autograft (QPA) size and pre-operative MRI measurements of the quadriceps tendon along sections to be included in the graft harvest in adolescents. We also assessed association between graft diameter and anthropometric measures (height, weight, and BMI), age, and sex.

METHODS: Patients (10-18 years) who underwent QPA ACL reconstruction and had a pre-operative MRI were considered for inclusion. Age, height, and weight, tibial and femoral side graft diameter, and patellar bone block dimensions were collected. Using a pre-operative 2D sagittal plane MRI, we measured the quadriceps at 10-mm increments above the patella, up to 40 mm. We assessed correlation between the bone-end graft diameter and the AP measure at 10 mm above the patella, and correlation between the soft-tissue end graft diameter and the most proximal AP measure.

RESULTS: A total of 103 patients were included. A significant correlation between the soft-tissue side graft diameter and most proximal AP measurement was observed (rs = 0.51; p < 0.001). However, measurements significantly underestimated the soft-tissue end graft diameter (9.6 ± 0.8 vs. 7.4 ± 1.1; p < 0.001). There was no correlation between the bone-end graft diameter and AP measurement 10 mm above the patella. Anthropometric measures were not associated with graft size. Skeletal maturity was associated with smaller graft size (p = 0.08).

CONCLUSION: Soft-tissue end graft diameter is associated with the AP measure of the quadriceps at 20-40 mm above the superior pole of the patella.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Gagliardi AG, Howell DR, Stein JM, et al. Prediction of quadriceps tendon-patellar bone autograft diameter in adolescents with 2-dimensional magnetic resonance imaging and anthropometric measures. Skeletal Radiol. 2021. PMID: 34291324. doi:10.1007/s00256-021-03874-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。