文献速递骨肌技术与安全MR

六点DIXON与磁共振波谱技术在镰状细胞病骨髓脂肪定量中的比较

Six-point DIXON and Magnetic Resonance Spectroscopy Techniques in Quantifying Bone Marrow Fat in Sickle Cell Disease.
PubMed 文献 · Acad Radiol · 2021-07-11

前瞻性研究纳入43例镰状细胞病患者(24例SS型,19例SC型)和41名健康对照,比较L3椎体六点DIXON(6PD)与单 voxel MRS的脂肪定量。6PD脂肪分数与MRS总脂质和饱和脂质高度相关(r=0.932和0.934,p<0.001),6PD与MRS诊断性能相似,6PD处理时间更短且覆盖范围更大。

要点

  • 6PD与MRS脂肪定量在SCD患者中高度相关,尤其SS亚组一致性最佳。
  • 6PD诊断SCD与健康对照的AUC为0.924,MRS总脂质AUC为0.883,饱和脂质AUC为0.892。
  • 6PD优势在于处理时间短、覆盖面积大,可替代MRS用于骨髓脂肪定量。

局限性

  • 单中心前瞻性研究,样本量有限。
  • 仅评估L3椎体,未涵盖其他部位。
  • 未报告重复性及观察者间一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To compare bone marrow fat quantification using magnetic resonance spectroscopy (MRS) and six-point DIXON (6PD) techniques in patients with sickle cell disease (SCD) and healthy subjects.

MATERIALS AND METHODS: Prospective study, with 43 SCD patients (24 homozygous [SS], 19 double heterozygous [SC), and 41 healthy subjects paired by age, weight and sex with SCD patients. All participants underwent magnetic resonance imaging with 6PD and single voxel MRS in the L3 vertebral body. Pearson's correlation, ROC curve, and bland-altman analysis were performed, p-values ≤0.05 were considered statistically significant for all tests.

RESULTS: Significant linear correlation was found between fat fraction (FF) by 6PD and Total Lipids (TL) (r = 0.932; p < 0.001) and Saturated Lipids (SL) (r = 0.934; p < 0.001), in all subjects. Strong correlations were also identified considering subjects of the SS/SC subgroups. Despite high correlations, no significant difference was observed only between FF and SL in the SS subgroup (Bland-Altman analysis), indicating excellent agreement between the fat estimations in this specific situation. Significant differences were observed in all variables (FF, TL, SL) comparing the SCD and healthy subjects. The ROC curve between SCD and healthy subjects showed the following areas under the curve: FF(0.924) > TL(0.883) > SL(0.892).

CONCLUSIONS: The comparison between fat quantification by the 6PD with MRS demonstrated an excellent correlation in SCD patients, especially in the SS subgroup, which usually has a higher degree of hemolysis. The diagnostic performance of 6PD and MRS is similar, with advantages of shorter imaging processing time and larger studied area with the 6PD.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Lins CF, Salmon CEG, de Souza LA, et al. Six-point DIXON and Magnetic Resonance Spectroscopy Techniques in Quantifying Bone Marrow Fat in Sickle Cell Disease. Acad Radiol. 2021. PMID: 34257024. doi:10.1016/j.acra.2021.06.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。