文献速递骨肌MR

不同MRI序列评估髌股关节骨关节炎骨髓水肿样病变的比较

Assessment of bone marrow oedema-like lesions using MRI in patellofemoral knee osteoarthritis: comparison of different MRI pulse sequences.
PubMed 文献 · Br J Radiol · 2021-07-14

研究纳入76例有症状的髌股关节骨关节炎患者,在1.5T MRI上比较PD脂肪抑制、STIR、增强T1W脂肪抑制和3D T1W FFE四种序列测量骨髓水肿样病变体积的差异。结果显示T1W FFE序列测量的体积显著小于其他序列且信度较低,而PD脂肪抑制、STIR和增强T1W脂肪抑制序列间相关性高、信度优秀;各序列测量的病变体积与膝痛均无显著关联。

要点

  • 评估髌股关节骨髓水肿样病变体积时,优先选用PD脂肪抑制或STIR序列,其信度优秀且与增强序列高度相关。
  • 3D T1W FFE序列测量的病变体积明显偏小、信度仅良好,不宜单独用于体积定量。
  • 骨髓水肿样病变体积与膝痛无显著关联,报告时不应仅凭体积推断症状严重程度。

关键影像表现/征象

  • 58例受试者至少在一个序列上存在髌股关节骨髓水肿样病变。
  • T1W FFE序列测量的病变体积中位数显著小于其他三个序列(224.7 mm³,IQR 82.50–607.95)。
  • 增强序列测量的病变体积最大(1129.8 mm³,IQR 467.28–3166.02)。
  • PD脂肪抑制与STIR序列测量的体积较增强序列略低,比例差异分别为0.79(95%CI 0.62–1.01)和0.85(95%CI 0.67–1.08)。

诊断标准与关键数值

  • PD脂肪抑制、STIR和增强T1W脂肪抑制序列间病变体积高度相关(ρs=0.98)。
  • 上述三个序列与T1W FFE序列间的相关性较低(ρs=0.80–0.81)。
  • PD脂肪抑制、STIR和增强T1W脂肪抑制序列的组内相关系数优秀(0.991–0.995),T1W FFE序列良好(0.88)。
  • 各序列测量的骨髓水肿样病变体积与膝痛均无显著关联。

临床应用与阅片要点

  • 日常定量骨髓水肿样病变体积时,可选用PD脂肪抑制或STIR序列,避免使用T1W FFE序列单独测量。
  • 增强T1W脂肪抑制序列测量值最大,但在无增强情况下PD脂肪抑制或STIR序列可提供高度一致的相对体积信息。
  • 报告骨髓水肿样病变体积时需注明所用序列,因不同序列间体积差异明显且不可直接互换。

局限性

  • 单中心研究,仅由一名阅片者评估,重复评估仅限15个膝关节。
  • 样本为有症状的髌股关节骨关节炎患者,结论外推至其他人群需谨慎。
  • 未报告序列间体积差异的统计学显著性检验细节(除T1W FFE外)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare bone marrow oedema-like lesion (BML) volume in subjects with symptomatic patellofemoral (PF) knee osteoarthritis (OA) using four different MRI sequences and to determine reliability of BML volume assessment using these sequences and their correlation with pain.

METHODS: 76 males and females (mean age 55.8 years) with symptomatic patellofemoral knee OA had 1.5 T MRI scans. PD fat suppressed (FS), STIR, contrast-enhanced (CE) T1W FS, and 3D T1W fast field echo (FFE) sequences were obtained. All sequences were assessed by one reader, including repeat assessment of 15 knees using manual segmentation and the measurements were compared. We used random-effects panel linear regression to look for differences in the log-transformed BML volume (due to positive skew in the BML volume distribution) between sequences and to determine associations between BML volumes and knee pain.

RESULTS: 58 subjects had PF BMLs present on at least one sequence. Median BML volume measured using T1W FFE sequence was significantly smaller (224.7 mm3, interquartile range [IQR] 82.50-607.95) than the other three sequences. BML volume was greatest on the CE sequence (1129.8 mm3, IQR 467.28-3166.02). Compared to CE sequence, BML volumes were slightly lower when assessed using PDFS (proportional difference = 0.79; 95% confidence interval [CI] 0.62, 1.01) and STIR sequences (proportional difference = 0.85; 95% CI 0.67, 1.08). There were strong correlations between BML volume on PDFS, STIR, and CE T1W FS sequences (ρs = 0.98). Correlations were lower between these three sequences and T1W FFE (ρs = 0.80-0.81). Intraclass correlation coefficients were excellent for proton density fat-suppressed, short-tau inversion recovery, and CE T1W FS sequences (0.991-0.995), while the ICC for T1W FFE was good at 0.88. We found no significant association between BML volumes assessed using any of the sequences and knee pain.

CONCLUSION: T1W FFE sequences were less reliable and measured considerably smaller BML volume compared to other sequences. BML volume was larger when assessed using the contrast enhanced T1W FS though not statistically significantly different from BMLs when assessed using PDFS and STIR sequences.

ADVANCES IN KNOWLEDGE: This is the first study to assess BMLs by four different MRI pulse sequences on the same data set, including different fluid sensitive sequences and gradient echo type sequence.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Noorveriandi H, Parkes MJ, Callaghan MJ, et al. Assessment of bone marrow oedema-like lesions using MRI in patellofemoral knee osteoarthritis: comparison of different MRI pulse sequences. Br J Radiol. 2021. PMID: 34233484. doi:10.1259/bjr.20201367

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。