MRI诊断Ramp损伤的准确性
两位放射科医生盲法阅片,仅发现内侧半月板后角与关节囊之间完全液体填充这一征象与Ramp损伤显著相关(P<0.01),其特异度84%、敏感度75%、阳性预测值56%、阴性预测值93%,观察者间一致性良好(k=0.79)。结论认为该征象是唯一显著的MRI病理征象,诊断准确性中等。
要点
- 内侧半月板后角与关节囊间完全液体填充是Ramp损伤唯一显著MRI征象
- 该征象敏感度75%、特异度84%,阴性预测值高达93%
- 观察者间一致性良好(k=0.79),但阳性预测值仅56%
核心结论
- 完全液体填充是Ramp损伤唯一有统计学意义的MRI征象,诊断准确性中等。
研究设计与样本
- 以关节镜为金标准,两位分别有5年和14年经验的放射科医生盲法阅片。
- 采用单因素及多因素逻辑回归分析,计算诊断准确性指标和观察者间一致性。
关键影像表现/征象
- 评估的MRI征象包括:内侧半月板后角与关节囊间完全液体填充、内侧半月板后壁不规则、关节囊水肿、与内侧半月板接触的液体高信号、内侧半月板前移。
- 仅内侧半月板后角与关节囊间完全液体高信号与Ramp损伤显著相关(P<0.01)。
诊断标准与关键数值
- 完全液体填充征象诊断Ramp损伤的敏感度75%、特异度84%、阳性预测值56%、阴性预测值93%,观察者间一致性k=0.79。
临床应用与阅片要点
- 阅片时应重点观察内侧半月板后角与关节囊之间是否存在完全液体填充,该征象阴性预测值高,有助于排除Ramp损伤。
- 阳性预测值较低,需结合其他征象及临床情况综合判断,避免过度诊断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic accuracy of MRI in diagnosing ramp lesions in patients with an acute lesion of the anterior cruciate ligament (ACL).
MATERIALS AND METHODS: All consecutive patients over 15 years of age who underwent surgical repair of the ACL at a single hospital between January and May 2019, with MRI data available, were included in this retrospective study, except patients who had previous knee surgery. The gold standard was arthroscopic evaluation. Two trained radiologists with 5 and 14 years of experience did a blinded review of the MRIs. The following pathological signs were studied: complete fluid filling between the capsule and the posterior horn of the medial meniscus, irregular appearance of the posterior wall of the medial meniscus, oedema of the capsule, fluid hyperintensity in contact with the medial meniscus and anterior subluxation of the medial meniscus. Logistic regressions in univariate then multivariate analysis were carried out and measures of diagnostic accuracy and interobserver agreement were calculated with R software (version 3.6).
RESULTS: Fifty-seven patients were included. Twelve had a ramp lesion diagnosed by arthroscopy (21%). Only complete fluid hyperintensity between the posterior horn of the medial meniscus and the capsule was significantly associated with ramp lesions (P value < 0.01). The diagnostic accuracy of this specific sign was moderate, with a specificity of 84%, sensitivity of 75%, PPV of 56%, NPV of 93% and a good level of inter-observer agreement (k = 0.79).
CONCLUSION: The complete fluid filling is the only significant pathological MRI sign for ramp lesions, with moderate accuracy.
引用
- Laurens M, Cavaignac E, Fayolle H, et al. The accuracy of MRI for the diagnosis of ramp lesions. Skeletal Radiol. 2021. PMID: 34216246. doi:10.1007/s00256-021-03858-w