甲状腺乳头状癌MRI影像组学:多种分类器建模预测颈部淋巴结转移的术前对比研究
本研究回顾性分析109例甲状腺乳头状癌(PTC)患者术前MRI,其中77例有淋巴结转移、32例无转移,基于脂肪抑制T2WI提取影像组学特征并构建8种分类器模型。逻辑回归分类器基于5个最优特征在训练组和验证组的AUC分别为0.805和0.760,最佳影像组学模型联合肉眼纹理诊断的AUC达0.969(敏感度0.938,特异度1.000)。联合模型有望在术前有效预测PTC颈部淋巴结转移。
要点
- 基于5个MRI影像组学特征的逻辑回归模型可术前预测PTC淋巴结转移,验证组AUC 0.760。
- 影像组学模型联合肉眼MRI纹理诊断的AUC达0.969,特异度1.000,诊断效能更优。
- 肉眼判读MRI纹理诊断淋巴结状态的AUC为0.739,敏感度0.571、特异度0.906。
关键影像表现/征象
- 肉眼判读MRI纹理诊断淋巴结状态的AUC为0.739(敏感度0.571,特异度0.906)。
- 基于5个最优特征的逻辑回归影像组学模型训练组AUC为0.805、验证组AUC为0.760。
- 最佳影像组学模型联合MRI纹理肉眼诊断的AUC高达0.969(敏感度0.938,特异度1.000)。
诊断标准与关键数值
- 影像组学特征源自脂肪抑制T2WI,最优特征经Spearman相关检验、假设检验和随机森林方法确认。
- 逻辑回归分类器基于5个最优特征建模,训练组AUC 0.805、验证组AUC 0.760。
- 联合模型(最佳影像组学模型+MRI纹理肉眼诊断)AUC 0.969,敏感度0.938,特异度1.000。
临床应用与阅片要点
- 术前可基于脂肪抑制T2WI提取影像组学特征辅助预判PTC颈部淋巴结转移风险。
- 联合影像组学模型与肉眼MRI纹理诊断可提高诊断效能,阅片时注意结合纹理特征。
- 本研究为单中心回顾性设计,模型外推需外部验证,注意过拟合风险。
局限性
- 回顾性研究设计,样本量有限(109例),可能存在选择偏倚。
- 单中心数据,缺乏外部验证,模型泛化能力有待证实。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare predictive efficiency of multiple classifiers modeling and establish a combined magnetic resonance imaging (MRI) radiomics model for identifying lymph node (LN) metastases of papillary thyroid cancer (PTC) preoperatively.
MATERIALS AND METHODS: A retrospective analysis based on the preoperative MRI scans of 109 PTC patients including 77 patients with LN metastases and 32 patients without metastases was conducted, and we divided enroll cases into trained group and validation group. Radiomics signatures were selected from fat-suppressed T2-weighted MRI images, and the optimal characteristics were confirmed by spearman correlation test, hypothesis testing and random forest methods, and then, eight predictive models were constructed by eight classifiers. The receiver operating characteristic (ROC) curves analysis were performed to demonstrate the effectiveness of the models.
RESULTS: The area under the curve (AUC) of ROC based on MRI texture diagnosed LN status by naked eye was 0.739 (sensitivity = 0.571, specificity = 0.906). Based on the 5 optimal signatures, the best AUC of MRI radiomics model by logistics regression classifier had a considerable prediction performance with AUCs 0.805 in trained group and 0.760 in validation group, respectively, and a combination of best radiomics model with visual diagnosis of MRI texture had a high AUC as 0.969 (sensitivity = 0.938, specificity = 1.000), suggesting combined model had a preferable diagnostic efficiency in evaluating LN metastases of PTC.
CONCLUSION: Our combined radiomics model with visual diagnosis could be a potentially effective strategy to preoperatively predict LN metastases in PTC patients before clinical intervention.
引用
- Qin H, Que Q, Lin P, et al. Magnetic resonance imaging (MRI) radiomics of papillary thyroid cancer (PTC): a comparison of predictive performance of multiple classifiers modeling to identify cervical lymph node metastases before surgery. Radiol Med. 2021. PMID: 34236572. doi:10.1007/s11547-021-01393-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。