乳腺MRI非肿块强化预测乳头受累的前瞻性诊断准确性研究
单中心前瞻性研究纳入64例乳腺MRI上距乳头2 cm内存在非肿块强化(NME)且手术切除乳头乳晕复合体的乳腺癌患者,评估NME延伸至乳头对病理乳头受累的预测价值。NME延伸至乳头者占77%(49/64),其阳性预测值为86%(95%CI: 73, 94),诊断准确性为88%(95%CI: 77, 95);无NME延伸者仅7%(1/15)有病理乳头受累。影像距离与病理距离相关性良好(Spearman r=0.71,P=.003)。
要点
- 乳腺MRI上NME延伸至乳头基底部对病理乳头受累有高阳性预测值(86%),支持将其视为保乳头手术的相对禁忌。
- 无NME延伸至乳头时病理乳头受累率很低(7%),提示可考虑保留乳头乳晕复合体。
- MRI所示NME至乳头的距离与病理距离相关性良好(r=0.71,P=.003),可用于术前评估。
关键影像表现/征象
- 评估的是与活检证实肿瘤病灶同侧且连续的NME延伸,基于早期增强期图像判断。
- 49例(77%)存在NME延伸至乳头,其中42例病理证实乳头受累。
- 15例无NME延伸至乳头者中仅1例(7%)病理乳头受累。
诊断标准与关键数值
- NME延伸至乳头的阳性预测值为86%(42/49;95%CI: 73, 94)。
- 以NME延伸至乳头预测病理乳头受累的诊断准确性为88%(56/64;95%CI: 77, 95)。
- MRI所示NME至乳头距离与病理距离的Spearman相关系数为0.71(P=.003)。
临床应用与阅片要点
- 术前MRI发现NME连续延伸至乳头基底部时,应警惕病理乳头受累,报告需明确描述NME与乳头的空间关系。
- 无NME延伸至乳头者病理乳头受累率低,可为保留乳头乳晕复合体手术提供依据。
- 应基于早期增强期图像评估NME延伸,并测量NME至乳头的距离以辅助手术规划。
局限性
- 单中心前瞻性研究,样本量64例,结论外推需谨慎。
- 仅纳入MRI上距乳头2 cm内存在NME且切除乳头乳晕复合体的患者,存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Although nonmass enhancement (NME) extension to the nipple at preoperative MRI frequently leads to sacrifice of the nipple-areolar complex (NAC), its correlation with pathologically confirmed NAC involvement is unclear. Purpose To evaluate the diagnostic accuracy of using NME extension to the subareolar region at breast MRI to predict pathologic nipple involvement and the eligibility for nipple-sparing mastectomy. Materials and Methods From November 2017 to November 2019, the authors prospectively enrolled participants with breast cancer and NME within 2 cm of the nipple at breast MRI who underwent surgery that included removal of the NAC. The authors evaluated NME extensions that were ipsilateral and contiguous with the biopsy-proven tumor lesions on images acquired during the early contrast phases. Pathologic nipple involvement and the distance from the nipple to the nearest cancer cell were evaluated by using serial vertical sectioning of the area extending from the entire NAC to the tumor. The primary end point was the positive predictive value (PPV) of NME, which was calculated as follows: (number with pathologic nipple invasion and NME extension to the nipple at breast MRI/number with NME extension to the nipple at breast MRI) × 100. Results Of 64 women (mean age, 52 years ± 9.8 [standard deviation]), 49 (77%) had NME extension to the nipple at breast MRI. The PPV of NME extension to the nipple was 86% (42 of 49 women; 95% CI: 73, 94). Among the 15 participants without NME extension to the nipple, only one (7%) had pathologic nipple involvement. The diagnostic accuracy of using NME extension to the nipple was 88% (56 of 64 women; 95% CI: 77, 95). The radiologic distance correlated well with the pathologic distance (Spearman correlation coefficient = 0.71, P = .003). Conclusion Nonmass enhancement extension to the nipple base at preoperative MRI has a high positive predictive value for identifying tumor involvement of the nipple, a contraindication to nipple-sparing mastectomy. © RSNA, 2021 Online supplemental material is available for this article.
引用
- Bae SJ, Cha YJ, Eun NL, et al. Diagnostic Accuracy of Nonmass Enhancement at Breast MRI in Predicting Tumor Involvement of the Nipple: A Prospective Study in a Single Institution. Radiology. 2021. PMID: 34254854. doi:10.1148/radiol.2021204136
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。