文献速递乳腺乳腺X线

对比增强乳腺X线摄影与数字乳腺X线摄影联合数字乳腺断层摄影在乳腺癌术前评估中的多阅片者比较

Multireader comparison of contrast-enhanced mammography versus the combination of digital mammography and digital breast tomosynthesis in the preoperative assessment of breast cancer.
PubMed 文献 · Radiol Med · 2021-07-24

该回顾性研究纳入78例经组织学确诊的乳腺癌患者,比较术前对比增强乳腺X线摄影(CEM)与数字乳腺X线摄影联合数字乳腺断层摄影(DM+DBT)在检测乳腺癌及评估其大小方面的性能。四位阅片者独立评估,结果显示CEM在经验较少的阅片者中总体癌症检出率更高,对额外病灶的检出率更高,尤其在致密乳腺中;两种方法在癌症大小评估方面表现相当。

要点

  • CEM对额外病灶的检出率高于DM+DBT,尤其在致密乳腺中。
  • 经验较少的阅片者使用CEM时总体癌症检出率更高。
  • CEM与DM+DBT在评估癌症大小方面表现相当。

局限性

  • 回顾性研究设计
  • 单中心研究
  • 样本量有限(78例患者)

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare preoperative contrast-enhanced spectral mammography (CEM) versus digital mammography plus digital breast tomosynthesis (DM + DBT) in detecting breast cancer (BC) and assessing its size.

MATERIAL AND METHODS: We retrospectively included 78 patients with histological diagnosis of BC who underwent preoperative DM, DBT, and CEM over one year. Four readers, blinded to pathology and clinical information, independently evaluated DM + DBT versus CEM to detect BC and measure its size. Readers' experience ranged 3-10 years. We calculated the per-lesion cancer detection rate (CDR) and the complement of positive predictive value (1-PPV) of both methods, stratifying analysis on the total of lesions, index lesions, and additional lesions. The agreement in assessing cancer size versus pathology was assessed with Bland-Altman analysis.

RESULTS: 100 invasive BCs (78 index lesions and 22 additional lesions) were analyzed. Compared to DM + DBT, CEM showed higher overall CDR in less experienced readers (range 0.85-0.90 vs. 0.95-0.96), and higher CDR for additional lesions, regardless of the reader (range 0.54-0.68 vs. 0.77-0.86). CEM increased the detection of additional disease in dense breasts in all readers and non-dense breasts in less experienced readers only. The 1-PPV of CEM (range 0.10-0.18) was comparable to that of DM + DBT (range 0.09-0.19). At Bland-Altman analysis, DM + DBT and CEM showed comparable mean differences and limits of agreement in respect of pathologic cancer size.

CONCLUSION: Preoperative CEM improved the detection of additional cancer lesions compared to DM + DBT, particularly in dense breasts. CEM and DM + DBT achieved comparable performance in cancer size assessment.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Girometti R, Linda A, Conte P, et al. Multireader comparison of contrast-enhanced mammography versus the combination of digital mammography and digital breast tomosynthesis in the preoperative assessment of breast cancer. Radiol Med. 2021. PMID: 34302599. doi:10.1007/s11547-021-01400-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。