文献速递乳腺乳腺X线

对比增强乳腺摄影病灶周围影像组学分析鉴别乳腺良恶性病变的诊断效能

Diagnostic performance of perilesional radiomics analysis of contrast-enhanced mammography for the differentiation of benign and malignant breast lesions.
PubMed 文献 · Eur Radiol · 2021-06-29

本研究回顾性纳入190例患者223个乳腺病变,基于对比增强乳腺摄影图像提取病灶及周围环形区域的影像组学特征,构建7个LASSO分类模型。测试集中,3 mm环形周围区域模型AUC最高(0.930),联合病灶与3 mm环形区域预测概率的新模型AUC达0.940,提示周围区域信息有补充价值。

要点

  • 3 mm环形病灶周围区域的影像组学模型在测试集AUC达0.930,优于病灶区模型(0.909)。
  • 联合病灶区与3 mm环形周围区域的预测概率可进一步提升诊断效能(AUC=0.940)。
  • 病灶周围影像组学信息与病灶本身信息具有互补性,阅片时可关注瘤周区域。

核心结论

  • 对比增强乳腺摄影图像的环形病灶周围区域影像组学分析有助于乳腺良恶性病变的鉴别诊断。
  • 将环形周围区域信息加入基于病灶区域的影像组学模型可能提高诊断效能。

研究设计与样本

  • 手动勾画病灶轮廓并自动获取周围区域,每个病灶得到7个感兴趣区(病灶区、1 mm/3 mm/5 mm环形周围区、病灶+1 mm/3 mm/5 mm周围区)。
  • 每个感兴趣区提取4098个影像组学特征,数据集按1:1分为训练集和测试集,采用LASSO回归构建7个分类模型,以AUC及95%CI评估模型性能。

诊断标准与关键数值

  • 测试集中,3 mm环形周围区模型AUC最高为0.930(95%CI:0.882-0.977)。
  • 1 mm环形周围区模型AUC为0.929(95%CI:0.881-0.978),病灶区模型AUC为0.909(95%CI:0.857-0.961)。
  • 联合病灶区与3 mm环形周围区模型预测概率的新模型在测试集AUC为0.940。

临床应用与阅片要点

  • 在对比增强乳腺摄影影像组学分析中,可考虑将病灶周围3 mm环形区域纳入特征提取范围以辅助鉴别良恶性。
  • 病灶周围区域影像组学特征与病灶本身特征具有互补性,联合建模可能提升诊断性能。

局限性

  • 本研究为回顾性单中心研究,样本量有限(190例223个病变)。
  • 模型性能仅在内部测试集验证,缺乏外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To conduct perilesional region radiomics analysis of contrast-enhanced mammography (CEM) images to differentiate benign and malignant breast lesions.

METHODS AND MATERIALS: This retrospective study included patients who underwent CEM from November 2017 to February 2020. Lesion contours were manually delineated. Perilesional regions were automatically obtained. Seven regions of interest (ROIs) were obtained for each lesion, including the lesion ROI, annular perilesional ROIs (1 mm, 3 mm, 5 mm), and lesion + perilesional ROIs (1 mm, 3 mm, 5 mm). Overall, 4,098 radiomics features were extracted from each ROI. Datasets were divided into training and testing sets (1:1). Seven classification models using features from the seven ROIs were constructed using LASSO regression. Model performance was assessed by the AUC with 95% CI.

RESULTS: Overall, 190 women with 223 breast lesions (101 benign; 122 malignant) were enrolled. In the testing set, the annular perilesional ROI of 3-mm model showed the highest AUC of 0.930 (95% CI: 0.882-0.977), followed by the annular perilesional ROI of 1 mm model (AUC = 0.929; 95% CI: 0.881-0.978) and the lesion ROI model (AUC = 0.909; 95% CI: 0.857-0.961). A new model was generated by combining the predicted probabilities of the lesion ROI and annular perilesional ROI of 3-mm models, which achieved a higher AUC in the testing set (AUC = 0.940).

CONCLUSIONS: Annular perilesional radiomics analysis of CEM images is useful for diagnosing breast cancers. Adding annular perilesional information to the radiomics model built on the lesion information may improve the diagnostic performance.

KEY POINTS: • Radiomics analysis of the annular perilesional region of 3 mm in CEM images may provide valuable information for the differential diagnosis of benign and malignant breast lesions. • The radiomics information from the lesion region and the annular perilesional region may be complementary. Combining the predicted probabilities of the models constructed by the features from the two regions may improve the diagnostic performance of radiomics models.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wang S, Sun Y, Li R, et al. Diagnostic performance of perilesional radiomics analysis of contrast-enhanced mammography for the differentiation of benign and malignant breast lesions. Eur Radiol. 2021. PMID: 34189600. doi:10.1007/s00330-021-08134-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。