双层光谱CT可鉴别乳腺良恶性病灶
这项双中心回顾性研究纳入106个乳腺肿块,评估双层光谱CT数据集能否判断其生物学性质。碘含量、单能曲线斜率和有效原子序数Zeff的AUC均高于常规密度,将病灶碘含量归一化至主动脉后鉴别效能最佳。
要点
- 光谱CT碘含量、单能曲线斜率、Zeff鉴别乳腺肿块良恶性优于常规CT密度。
- 病灶碘含量最佳截断值0.7-0.9 mg/ml,敏感度96.6%,特异度91.7%。
- 碘含量归一化至主动脉后特异度提升至91.7%,敏感度95.5%。
核心结论
- 光谱CT数据集有望在临床胸部CT检查中评估乳腺肿块的生物学性质,鉴别良恶性。
研究设计与样本
- 双中心回顾性研究,纳入2017年7月至2019年6月经光谱CT检查显示乳腺肿块的患者,共106个肿块。
- 恶性81个、良性25个,良恶性分别占76.4%和23.6%,依据组织学或稳定随访超过2年进行定性。
- 由两名独立读者评估常规CT图像、碘密度图、虚拟单能图像(40 keV、100 keV)和有效原子序数图,基于感兴趣区计算ROC曲线下面积和Youden指数。
诊断标准与关键数值
- 目标病灶碘含量、单能曲线斜率、Zeffective的AUC分别为0.97/0.98、0.97/0.96、0.98/0.98(读者1/2),均优于密度(AUC 0.92/0.93,p<0.001)。
- 目标病灶碘含量最佳截断值为0.7-0.9 mg/ml,敏感度96.6%,特异度91.7%。
- 将目标病灶碘含量归一化至主动脉后诊断效能最佳,最佳截断值0.1,敏感度95.5%,特异度91.7%。
- 病灶与主动脉比值在碘含量、单能曲线斜率和Zeffective变量上均优于正常乳腺组织和肌肉(p<0.001)。
临床应用与阅片要点
- 对于胸部增强CT中偶然发现的乳腺肿块,可借助光谱CT碘密度图或有效原子序数图辅助判断良恶性。
- 建议将病灶碘含量与主动脉碘含量进行归一化,以提高鉴别特异性。
局限性
- 本研究为双中心回顾性研究,样本量有限,结果需前瞻性验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Intramammary mass lesions are reportedly present in up to 5.8% of all contrast enhanced CT-examinations of the female chest. We aimed to assess whether their biological relevance can be estimated using spectral CT-datasets.
METHODS: In this bicentric retrospective study patients with breast masses visualized on spectral CT-examinations from 07/2017 to 06/2019 were included. Lesions were characterized as malignant or benign based on histology and/or a stable follow-up of >2 years. Conventional CT-images, iodine density-maps, virtual monoenergetic-images (40 keV, 100 keV) and Zeffective-maps were evaluated by two independent readers. Statistical analysis derived from the Regions of interest (ROIs) was done by calculating the Areas under the Receiver operating characteristic (ROC) curve (AUC) and Youden-indices.
RESULTS: 106 breast masses (malignant/benign: 81/25, 76.4%/23.6%) were included. The mean AUCs of the variables "iodine content" (reader 1/2:0.97;0.98), "monoenergetic curve-slope" (0.97;0.96) and "Zeffective" (0.98;0.98) measured in the target lesions (TL) showed superior results compared to those derived from the variable "density" (0.92;0.93) (p < 0.001). The ratios "TL to aorta" calculated for the variables "iodine content", "monoenergetic curve-slope" and "Zeffective" showed superior results compared to normal breast tissue and muscle (p < 0.001). The optimal cutpoint for the "iodine content" in the TL was 0.7-0.9 mg/ml (sensitivity 96.6%, specificity 91.7%). The best diagnostic results were achieved by normalizing the iodine content in the TL to that in the aorta (optimal cutpoint 0.1, sensitivity 95.5%, 98.9%, specificity 91.7%).
CONCLUSIONS: Our preliminary results suggest that spectral CT-datasets might allow to estimate the biological dignity of breast masses detected on clinically indicated chest-examinations.