文献速递妇产影像外周血管介入MR

1.5 T与3 T非增强MR血管成像显示子宫动脉及卵巢动脉的比较

Comparison of 1.5 T and 3 T non-contrast-enhanced MR angiography for visualization of uterine and ovarian arteries before uterine artery embolization.
PubMed 文献 · Eur Radiol · 2021-06-30

本研究回顾性分析85例子宫肌瘤患者UAE术前的盆腔NCE-MRA图像,由两名专科医师对左右子宫动脉分别行5分法评分并比较增大卵巢动脉的检出。3 T对子宫动脉的显示评分中位5分(IQR 4-5),显著高于1.5 T的3分(IQR 2-4)(p<0.05);增大卵巢动脉检出1.5 T为7条、3 T为5条,差异无统计学意义(p=0.36)。

要点

  • UAE术前NCE-MRA可显示子宫动脉起源、走行及肿瘤侧支供血。
  • 3 T对子宫动脉远端及瘤周血管丛的显示优于1.5 T。
  • 两场强对增大卵巢动脉的检出无显著差异。

核心结论

  • 3 T NCE-MRA对子宫动脉的显示范围大于1.5 T,而对增大卵巢动脉的检出两者无差异。

研究设计与样本

  • 回顾性研究,纳入85例因症状性子宫肌瘤行UAE治疗的患者,术前行盆腔NCE-MRA,由两名盆腔MRI专科医师阅片。
  • 共评估170条子宫动脉,其中110条在1.5 T、60条在3 T完成检查,左右子宫动脉分别用5分法评分。
  • 采用Mann-Whitney U检验与Fisher精确检验,p<0.05为差异有统计学意义。

关键影像表现/征象

  • 子宫动脉按5分法评分:5分为子宫动脉可显示至肌层内并形成瘤周血管丛,1分为仅显示至降段。
  • 3 T子宫动脉显示评分中位5分(IQR 4-5),1.5 T中位3分(IQR 2-4)。
  • 增大卵巢动脉检出数:1.5 T为7条,3 T为5条。

诊断标准与关键数值

  • 子宫动脉显示采用5分法:最高5分(可见肌层内走行并形成瘤周血管丛),最低1分(仅见降段)。
  • 3 T较1.5 T子宫动脉显示评分显著更高(p<0.05)。
  • 增大卵巢动脉检出在两场强间无显著差异(p=0.36)。

临床应用与阅片要点

  • UAE术前可用NCE-MRA评估子宫动脉起源、走行及肿瘤侧支供血,为介入医师提供参考。
  • 对无法使用对比剂的患者,NCE-MRA是可选检查;条件允许时优先选用3 T设备以更好显示子宫动脉。
  • 阅片时应对左右子宫动脉分别按5分法评估,注意描述瘤周血管丛及卵巢动脉增粗情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare the performance of non-contrast-enhanced magnetic resonance angiography (NCE-MRA) at 1.5 T and 3 T for the visualization of uterine and ovarian arteries (OAs) before uterine artery embolization (UAE).

METHODS: Preprocedural pelvic NCE-MRA images of 85 symptomatic patients undergoing UAE for the treatment of uterine leiomyomas were reviewed by two specialists in pelvic MRI. Left and right uterine arteries (UAs) were judged separately and scored on a 5-point scale. Score 5 was the highest, in which the UA could be visualized inside the musculature, forming a peritumoral plexus. Score 1 was the lowest, where visualization was limited to the descending segment. The detection of enlarged OAs was also compared. The Mann-Whitney U and Fisher exact tests were used for statistical analysis. p < 0.05 was considered to be statistically significant.

RESULTS: Of the 170 UAs, 110 were classified at 1.5 T and 60 were classified at 3 T. Median (interquartile range [IQR]) score was 3 (IQR: 2-4) for visualization at 1.5 T vs 5 (IQR: 4-5) for 3 T. The scores for UA visualization were significantly higher at 3 T (p < 0.05). For enlarged OAs, NCE-MRA at 1.5 T and 3 T visualized 7 and 5 enlarged OAs, respectively; there was no significant difference between the two field strengths (p = 0.36).

CONCLUSIONS: NCE-MRA performed at 3 T can visualize UAs over a greater range than at 1.5 T. No difference was found regarding the detection of enlarged OAs.

KEY POINTS: • Preprocedural MRA can provide interventional radiologists with valuable information, including the origin and course of the uterine arteries and the existence of collateral feeders to the tumor. • This study demonstrates the superiority of non-contrast-enhanced MRA performed at 3 T over that performed at 1.5 T in the visualization of the uterine arteries in patients undergoing uterine artery embolization for the treatment of uterine leiomyomas. • Non-contrast-enhanced MRA is a useful imaging modality for patients with symptomatic leiomyoma undergoing uterine artery embolization in whom contrast administration is unfeasible. If available, it is preferable to perform the examination with a 3 T MR unit rather than a 1.5 T MR unit.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ishisaki JY, Kato H, Zhang X, et al. Comparison of 1.5 T and 3 T non-contrast-enhanced MR angiography for visualization of uterine and ovarian arteries before uterine artery embolization. Eur Radiol. 2021. PMID: 34195889. doi:10.1007/s00330-021-08141-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。