膀胱影像报告和数据系统(VI-RADS):各MRI序列在高级别NMIBC和MIBC诊断性能中是否等效?
本研究回顾性纳入59例膀胱癌患者,评估VI-RADS总分及各单一MRI序列(T2WI、DWI、DCE)对肿瘤分级和肌层浸润的诊断效能。结果显示VI-RADS总分诊断肌层浸润的AUC为0.986(R1)和0.992(R2),诊断高级别癌的AUC为0.908(R1)和0.905(R2);各单一参数与总分间AUC无显著差异(P>0.05)。多因素回归仅T2WI VI-RADS评分独立预测高级别和肌层浸润癌,提示双参数免对比增强扫描可能不牺牲诊断准确性。
要点
- VI-RADS总分对肌层浸润和高级别膀胱癌诊断准确性高(AUC>0.9)。
- T2WI、DWI、DCE各单一序列与VI-RADS总分诊断效能无显著差异。
- T2WI VI-RADS评分是独立预测因子,支持双参数免增强MRI的可行性。
关键影像表现/征象
- 膀胱癌组织中26例(51%)为高级别,14例(27.5%)为肌层浸润性尿路上皮癌。
- VI-RADS总分预测肌层浸润的AUC为0.986(R1)和0.992(R2)。
- VI-RADS总分诊断高级别膀胱癌的AUC为0.908(R1)和0.905(R2)。
- 各单一参数(T2WI、DWI、DCE)与VI-RADS总分的AUC无显著差异(P>0.05)。
诊断标准与关键数值
- VI-RADS总分预测肌层浸润:AUC 0.986(R1)、0.992(R2)。
- VI-RADS总分诊断高级别膀胱癌:AUC 0.908(R1)、0.905(R2)。
- 多因素logistic回归显示仅T2WI VI-RADS评分独立预测高级别癌(P=0.001 [R1]、P=0.0022 [R2])和肌层浸润(P=0.0007 [R1]、P=0.0019 [R2])。
临床应用与阅片要点
- 日常阅片可按VI-RADS评分评估膀胱癌肌层浸润和分级,总分诊断准确性高。
- T2WI VI-RADS评分独立预测高级别和肌层浸润,阅片时应重点关注。
- 若临床需简化流程,双参数免对比增强MRI(T2WI+DWI)可能不牺牲诊断准确性。
局限性
- 回顾性单中心设计,样本量有限(59例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the diagnostic performance of the overall Vesical Imaging Reporting and Data System (VI-RADS) score and its individual magnetic resonance imaging (MRI) parameters in assessing grade and muscle invasiveness of bladder cancer (BC).
METHODS: This IRB-approved retrospective, single-center, cross-sectional study included patients with BC wo underwent 3 Tesla preoperative multiparametric (mp)-MRI including T2-weighted (T2w), diffusion weighted imaging (DWI) and dynamic contrast enhanced (DCE) sequences. An independent evaluation according to VI-RADS was performed by two radiologists in separate sessions, blinded to histological findings.
RESULTS: The mean age of 59 included patients was 68.2 (±13.6 standard deviation) years. Among bladder cancer patients, 26 (51%) were identified as high grade and 14 (27.5%) as muscle invasive urothelial carcinomas in histological sections. The area under the curve (AUC) for the overall VI-RADS score to predict muscle invasion was 0.986 (R1) and 0.992 (R2). The AUC to diagnose high grade bladder cancer was 0.908 (R1) and 0.905 (R2). There was no significance difference between the AUC of single parameters (T2w, DWI and DCE) compared to the total VI-RADS score (P > 0.05, respectively). Upon multivariate logistic regression, only the T2w VI-RADS score contributed independently to the diagnosis of high grade and muscle invasive bladder cancer (P = 0.001 (R1) and P = 0.0022 (R2) for high grade cancer; P = 0.0007 (R1) and P = 0.0019 (R2) for muscle invasiveness).
CONCLUSION: VI-RADS provides high diagnostic accuracy to diagnose high grade and muscle invasive BC. Our results suggest, that mp-MRI parameters provide overlapping information and for sake of clinical simplicity, a biparametric, contrast free image acquisition may be approached without sacrificing diagnostic accuracy.
引用
- Gmeiner J, Garstka N, Helbich TH, et al. Vesical Imaging Reporting and Data System (VI-RADS): Are the individual MRI sequences equivalent in diagnostic performance of high grade NMIBC and MIBC? Eur J Radiol. 2021. PMID: 34252867. doi:10.1016/j.ejrad.2021.109829
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。