文献速递腹部MR

钆塞酸增强肝脏MRI动脉期短暂严重运动伪影的系统综述与荟萃分析

Transient Severe Motion Artifact on Arterial Phase in Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging: A Systematic Review and Meta-analysis.
PubMed 文献 · Invest Radiol · 2022-01-01

该系统综述与荟萃分析纳入24项研究,评估钆塞酸增强肝脏MRI动脉期短暂严重运动伪影(TSM)的发生率。单动脉期成像的TSM合并发生率为13.0%(95%CI 10.3%-16.2%),多动脉期成像为3.2%(95%CI 1.9%-5.2%),显著低于单动脉期(P<0.001)。研究地区与TSM定义是异质性的来源。

要点

  • 单动脉期钆塞酸增强肝脏MRI的TSM合并发生率为13.0%,多动脉期可降至3.2%。
  • TSM定义采用4分法或仅基于动脉期时报告的发生率更高。
  • 欧美人群研究TSM发生率高于亚太人群(16.0% vs 8.8%)。

核心结论

  • 动脉期TSM发生率在不同研究间存在差异,与研究方向的地理区域和TSM定义相关。
  • 多动脉期成像的TSM合并发生率显著低于单动脉期成像。

研究设计与样本

  • 系统综述与荟萃分析,检索PubMed、Embase和Cochrane Library数据库。
  • 最终纳入24项报告TSM发生率的原始研究;单动脉期19项研究共3065例受试者,多动脉期8项研究共2274例受试者。
  • 采用随机效应模型对单比例进行合并,并进行亚组分析探索异质性来源。

诊断标准与关键数值

  • 单动脉期成像研究报道的TSM个体发生率范围为4.8%至26.7%,合并发生率为13.0%(95%CI 10.3%-16.2%)。
  • 多动脉期成像研究的TSM合并发生率为3.2%(95%CI 1.9%-5.2%),显著低于单动脉期研究(P<0.001)。
  • 采用4分法定义TSM的研究合并发生率高于5分法(20.0% vs 11.0%,P=0.008)。
  • 仅基于动脉期定义TSM的研究合并发生率高于考虑其他期相运动伪影的定义(20.3% vs 11.3%,P=0.018)。
  • 欧美人群研究TSM合并发生率高于亚太人群(16.0% vs 8.8%,P=0.005)。

临床应用与阅片要点

  • 阅片时需注意钆塞酸增强肝脏MRI动脉期可能出现短暂严重运动伪影,单动脉期成像发生率较高。
  • 报告TSM相关结果时,应关注研究人群地理区域和TSM定义对发生率的影响。
  • 采用多动脉期成像可能降低TSM的发生率。

局限性

  • 研究间存在显著异质性,TSM定义和地理区域是异质性来源。
  • 原文未明确报告纳入研究的其他偏倚风险或质量评价细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aims of this study were to determine the incidence of transient severe motion artifact (TSM) on arterial phase gadoxetic acid-enhanced magnetic resonance imaging of the liver and to investigate the causes of heterogeneity in the published literature.

MATERIALS AND METHODS: Original studies reporting the incidence of TSM were identified in searches of PubMed, Embase, and Cochrane Library databases. The pooled incidence of TSM was calculated using random-effects meta-analysis of single proportions. Subgroup analyses were conducted to explore causes of heterogeneity.

RESULTS: A total of 24 studies were finally included (single arterial phase, 19 studies with 3065 subjects; multiple arterial phases, 8 studies with 2274 subjects). Studies using single arterial phase imaging reported individual TSM rates varying from 4.8% to 26.7% and a pooled incidence of TSM of 13.0% (95% confidence interval, 10.3%-16.2%), which showed substantial study heterogeneity. The pooled incidence of TSM in the studies using multiple arterial phase imaging was 3.2% (95% confidence interval, 1.9%-5.2%), which was significantly less than in those studies using single arterial phase imaging (P < 0.001). In the subgroup analysis, the geographical region of studies and the definition of TSM were found to be causes of heterogeneity. The incidence of TSM was higher in studies with Western populations from Europe or North America than in those with Eastern (Asia/Pacific) populations (16.0% vs 8.8%, P = 0.005). Regarding the definition of TSM, the incidence of TSM was higher when a 4-point scale was used for its categorization than when a 5-point scale was used (20.0% vs 11.0%, P = 0.008), and a definition considering motion artifact on phases other than arterial phase imaging lowered the incidence of TSM compared with it being defined only on arterial phase imaging (11.3% vs 20.3%, P = 0.018).

CONCLUSIONS: The incidence of TSM on arterial phase images varied across studies and was associated with the geographical region of studies and the definition of TSM. Careful interpretation of results reporting TSM might therefore be needed.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Kim DW, Choi SH, Park T, et al. Transient Severe Motion Artifact on Arterial Phase in Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging: A Systematic Review and Meta-analysis. Invest Radiol. 2022. PMID: 34224484. doi:10.1097/RLI.0000000000000806

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。