术前CT特征预测胃胃肠间质瘤Ki-67标记指数的价值
回顾性纳入167例术前行增强CT的胃GIST患者,比较Ki-67高表达组(>4%,n=125)与低表达组(≤4%,n=42)的CT形态学和定量特征。多因素分析显示分叶/不规则形状(OR=3.817,p=0.000)和高坏死体积比(OR=1.935,p=0.024)是高Ki-67LI的独立预测因素。
要点
- 分叶/不规则形状和高坏死体积比可独立预测胃GIST高Ki-67LI。
- 坏死体积比每增加单位,高Ki-67LI风险增加(OR=1.935)。
- 分叶/不规则形状者高Ki-67LI风险约为非分叶/规则形状者的3.8倍。
关键影像表现/征象
- 生长方式、形状、最大径、总肿瘤体积、总肿瘤平均CT值、坏死体积、坏死体积比、强化组织体积及强化组织平均CT值在两组间差异有统计学意义。
- 多因素分析显示分叶/不规则形状(OR=3.817,p=0.000)和高坏死体积比(OR=1.935,p=0.024)是高Ki-67LI的独立因素。
诊断标准与关键数值
- 以Ki-67LI>4%定义为高表达组,≤4%为低表达组。
- 分叶/不规则形状预测高Ki-67LI的OR=3.817(p=0.000)。
- 高坏死体积比预测高Ki-67LI的OR=1.935(p=0.024)。
临床应用与阅片要点
- 阅片时注意评估肿瘤形状是否分叶/不规则,并测量坏死体积比。
- 对分叶/不规则形状且坏死体积比高的胃GIST,可提示Ki-67可能高表达。
局限性
- 回顾性研究设计。
- 单中心样本。
- 原文未报告敏感度、特异度、AUC及阈值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the value of preoperative computed tomography (CT) features including morphologic and quantitative features for predicting the Ki-67 labeling index (Ki-67LI) of gastric gastrointestinal stromal tumors (GISTs).
METHODS: We retrospectively included 167 patients with gastric GISTs who underwent preoperative contrast-enhanced CT. We assessed the morphologic features of preoperative CT images and the quantitative features including the maximum diameter of tumor, total tumor volume, mean total tumor CT value, necrosis volume, necrosis volume ratio, enhanced tissue volume, and mean CT value of enhanced tissue. Potential predictive parameters to distinguish the high-level Ki-67LI group (>4%, n = 125) from the low-level Ki-67LI group (≤4%, n = 42) were compared and subsequently determined in multivariable logistic regression analysis.
RESULTS: Growth pattern (p = 0.036), shape (p = 0.000), maximum diameter (p = 0.018), total tumor volume (p = 0.021), mean total tumor CT value (p = 0.009), necrosis volume (p = 0.006), necrosis volume ratio (p = 0.000), enhanced tissue volume (p = 0.027), and mean CT value of enhanced tissue (p = 0.004) were significantly different between the two groups. Multivariate logistic regression analysis indicated that lobulated/irregular shape (odds ratio [OR] = 3.817; p = 0.000) and high necrosis volume ratio (OR = 1.935; p = 0.024) were independent factors of high-level Ki-67LI.
CONCLUSIONS: Higher necrosis volume ratio in combination with lobulated/irregular shape could potentially predict high expression of Ki-67LI for gastric GISTs.
引用
- Chen XS, Shan YC, Dong SY, et al. Utility of preoperative computed tomography features in predicting the Ki-67 labeling index of gastric gastrointestinal stromal tumors. Eur J Radiol. 2021. PMID: 34237492. doi:10.1016/j.ejrad.2021.109840
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。