文献速递腹部MR

压缩感知屏气3D MRCP与两种并行成像MRCP策略在主胰管和胆总管中的比较

Comparing compressed sensing breath-hold 3D MR cholangiopancreatography with two parallel imaging MRCP strategies in main pancreatic duct and common bile duct.
PubMed 文献 · Eur J Radiol · 2021-06-24

前瞻性纳入109例疑似胰胆疾病患者,比较3D-BH-PI-MRCP、3D-BH-CS-MRCP与3D-NT-MRCP的图像质量与一致性。CS-MRCP胆总管对比度、SNR和CNR更高,但PI-MRCP对肝内胆管2、3级分支及主胰管显示更优,且主胰管和胆总管形态一致性与NT-MRCP更好。

要点

  • 两种屏气MRCP均节省时间且不降低图像质量。
  • PI-MRCP对肝内胆管2、3级分支及主胰管显示优于CS-MRCP。
  • PI-MRCP在主胰管和胆总管形态一致性与NT-MRCP更好。

关键影像表现/征象

  • CS-MRCP的胆总管对比度、SNR和CNR显著高于NT-MRCP和PI-MRCP。
  • PI-MRCP与CS-MRCP对胆总管、右肝管、左肝管、前后分支和胆囊管的显示相似。
  • PI-MRCP对肝内胆管2或3级分支和主胰管的显示显著优于CS-MRCP和NT-MRCP(p < 0.001)。

临床应用与阅片要点

  • 需重点观察肝内胆管2、3级分支或主胰管细节时,优先选用PI-MRCP。
  • 关注胆总管信号强度时,CS-MRCP的对比度、SNR和CNR更高。
  • 两种屏气序列均可替代NT-MRCP以缩短检查时间,且不降低图像质量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the image quality and image consistency between 3D Breath-hold (BH)-MRCP with parallel imaging (3D-BH-PI-MRCP) and 3D-BH compressed sensing (CS)-MRCP (3D-BH-CS-MRCP) in patients with suspected pancreaticobiliary diseases, compared with 3D navigator-triggered (NT)-MRCP.

MATERIALS AND METHODS: The A total number of 109 patients who underwent 3D-NT-MRCP, 3D-BH-PI-MRCP and 3D-BH-CS-MRCP were prospectively enrolled in this study. The Friedman test was performed to compare quantitative values, image acquisition time, the presence of artifacts, overall image quality, and duct visualization among the three protocols. Additionally, we compared 3D-BH-PI-MRCP and 3D-BH-CS-MRCP with 3D-NT-MRCP in morphological consistency of main pancreatic duct and common bile duct (CBD) based on overall image quality score of = 4.

RESULTS: Three MRCP methods were successfully performed in all the patients. The contrast ratio, SNR and CNR of the CBD were significantly higher for 3D-BH-CS-MRCP than those for 3D-NT-MRCP and 3D-BH-PI-MRCP images. Overall image quality did differ significantly across the three sequences. Visualization of the CBD, RHD, LHD, anterior branch, posterior branch and cystic duct was similar with the 3D-BH-CS-MRCP and 3D-BH-PI-MRCP sequences. In contrast, segment 2 or 3 branch and main pancreatic duct visualization were significantly better with 3D-BH-PI-MRCP than with 3D-BH-CS-MRCP and 3D-NT-MRCP (p < 0.001).

CONCLUSIONS: Both the two breath-hold approaches were considering the time-saving advantages without deterioration of image quality. Compared with 3D-BH-CS-MRCP, 3D-BH-PI-MRCP yielded significantly better visualization of the segment 2 and 3 branch of the intrahepatic duct and performed better consistency in main pancreatic duct and common bile duct morphology.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen Z, Sun B, Xue Y, et al. Comparing compressed sensing breath-hold 3D MR cholangiopancreatography with two parallel imaging MRCP strategies in main pancreatic duct and common bile duct. Eur J Radiol. 2021. PMID: 34218123. doi:10.1016/j.ejrad.2021.109833

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。