文献速递腹部CT

双能CT碘图与低keV虚拟单能图像对急性胆囊炎的诊断价值

Acute cholecystitis: diagnostic value of dual-energy CT-derived iodine map and low-keV virtual monoenergetic images.
PubMed 文献 · Abdom Radiol (NY) · 2021-07-05

回顾性纳入57例病理证实的急性胆囊炎患者和57例无胆囊炎对照,比较常规CT与双能CT(含低keV虚拟单能图像和碘图)的诊断效能。双能CT提高了胆囊窝充血、坏疽、壁不均匀强化及急性胆囊炎的检出敏感度,碘密度阈值对坏疽性胆囊炎具有较高特异度。

要点

  • 双能CT可提高急性胆囊炎及坏疽的检出敏感度。
  • 碘密度测量有助于诊断坏疽性胆囊炎,特异度可达95.65%。
  • 胆囊窝充血和壁不均匀强化在双能CT上更易识别。

关键影像表现/征象

  • 双能CT检测胆囊窝充血的敏感度(R1 61.4%,R2 75.4%)高于CT(R1 22.8%,R2 15.8%)。
  • 双能CT检测坏疽的敏感度(R1 24.6%,R2 38.6%)高于CT(R1 5.3%,R2 14%)。
  • 双能CT检测壁不均匀强化的敏感度(R1 33.3%,R2 63.2%)高于CT(R1 7%,R2 31.6%)。
  • 双能CT诊断急性胆囊炎的敏感度(R1 86%,R2 89.5%)高于CT(R1 77.2%,R2 70.2%)。

诊断标准与关键数值

  • 使用rsDECT平台,碘密度阈值1.2 mg/ml诊断坏疽性胆囊炎的特异度为78.26%。
  • 使用rsDECT平台,碘密度阈值0.8 mg/mL诊断坏疽性胆囊炎的特异度为86.96%。
  • 使用rsDECT平台,碘密度阈值0.5 mg/mL诊断坏疽性胆囊炎的特异度为95.65%。

临床应用与阅片要点

  • 在急性胆囊炎评估中,可结合双能CT的低keV虚拟单能图像和碘图提高胆囊窝充血、壁不均匀强化及坏疽的检出。
  • 利用碘密度阈值(如0.5 mg/mL)辅助诊断坏疽性胆囊炎,注意其特异度较高但敏感度未报告。

局限性

  • 回顾性研究,样本量有限(57例胆囊炎和57例对照),单中心设计。
  • 原文未报告碘密度阈值的敏感度、AUC等完整诊断效能指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare conventional and dual-energy CT (DECT) for the diagnosis of acute cholecystitis and gangrene.

METHODS: Fifty-seven consecutive adult patients with abdominal pain who underwent IV contrast-enhanced abdominal DECT on a dual-layer (dlDECT) or rapid-switching (rsDECT) scanner from September, 2018 to April, 2021 with cholecystectomy and pathology-confirmed cholecystitis were retrospectively reviewed, and compared with 57 consecutive adult patients without cholecystitis from the same interval scanned with DECT. Images were reviewed independently by two abdominal radiologists with 12 and 16 years of experience in two sessions 4 weeks apart, blinded to clinical data. Initially, only blended reconstructions (simulating conventional single-energy CT images) were reviewed (CT). Subsequently, CT and DECT reconstructions including low-keV virtual monoenergetic images and iodine maps were reviewed. Gallbladder fossa hyperemia, pericholecystic fluid, subjective presence of gangrene, heterogeneous wall enhancement, sloughed membranes, intramural air, abscess, overall impression of the presence of acute cholecystitis, and intramural iodine density were assessed.

RESULTS: Gallbladder fossa hyperemia was detected with increased sensitivity on DECT (R1, 61.4%; R2, 75.4%) vs. CT (R1, 22.8%; R2, 15.8%). DECT showed increased sensitivity for gangrene (R1, 24.6%; R2, 38.6%) vs. CT (R1, 5.3%; R2, 14%), heterogeneous wall enhancement (DECT: R1, 33.3%; R2, 63.2% vs. CT: R1, 7%; R2, 31.6%), and cholecystitis (DECT: R1, 86%; R2, 89.5% vs. CT: R1, 77.2%; R2, 70.2%). In addition, DECT was more sensitive for the detection of acute cholecystitis (R1, 86%; R2, 89.5%) vs. CT (R1, 77.2%; R2, 70.2%). Iodine density threshold of 1.2 mg/ml, 0.8 mg/mL, and 0.5 mg/mL showed specificity for gangrenous cholecystitis of 78.26%, 86.96%, and 95.65%, respectively, using the rsDECT platform.

CONCLUSION: DECT showed improved sensitivity compared to conventional CT for detection of acute cholecystitis. Iodine density measurements may be helpful to diagnose gangrene.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Huda F, LeBedis CA, Qureshi MM, et al. Acute cholecystitis: diagnostic value of dual-energy CT-derived iodine map and low-keV virtual monoenergetic images. Abdom Radiol (NY). 2021. PMID: 34223959. doi:10.1007/s00261-021-03202-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。