超声LI-RADS可视化评分:观察者间一致性的可靠性分析
本研究回顾性分析6998例HCC超声筛查/监测研究,随机抽取90例(A/B/C各30例)由9名放射科医生独立评分。总体ICC为0.70(95%CI 0.63-0.77),不同年资医生及肝实质亚组ICC在0.58-0.76之间,表明US LI-RADS可视化评分具有良好观察者间一致性,可用于指示超声筛查检测局灶性肝脏病灶的预期敏感度。
要点
- US LI-RADS可视化评分总体观察者间一致性良好(ICC 0.70)。
- 肝硬化患者ICC最低(0.58),阅片时需注意评分一致性可能下降。
- 可视化评分可用于提示超声筛查的预期敏感度,辅助报告沟通。
关键影像表现/征象
- 可视化A(无或轻微限制)占87.9%(6154/6998),B(中度限制)占10.1%(709/6998),C(严重限制)占1.9%(135/6998)。
诊断标准与关键数值
- 所有9名医生间ICC为0.70(95%CI 0.63-0.77)。
- 高级主治、初级主治和腹部影像研究员ICC分别为0.68(95%CI 0.58-0.76)、0.72(95%CI 0.62-0.80)和0.76(95%CI 0.68-0.83)。
- 按肝实质亚组:正常肝实质ICC最高(0.69,95%CI 0.56-0.81),脂肪变性次之(0.66,95%CI 0.54-0.79),肝硬化最低(0.58,95%CI 0.43-0.73)。
临床应用与阅片要点
- 日常阅片可采用US LI-RADS可视化评分(A/B/C)来标准化描述超声筛查检查的局限性,并提示预期敏感度。
- 在肝硬化患者中评分一致性相对较低,报告时需更谨慎并注意描述图像质量限制。
局限性
- 回顾性研究设计。
- 样本来自单中心连续病例,但仅随机抽取90例进行分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND & AIM: The American College of Radiology Ultrasound Liver Imaging Reporting and Data System (ACR US LI-RADS) Visualization Score conveys the expected level of sensitivity of screening and surveillance ultrasound exams in patients at risk for hepatocellular carcinoma (HCC). We sought to determine inter-reader agreement of the Visualization Score which is currently unknown.
METHODS: Consecutive 6998 ultrasound HCC screening and surveillance studies in 3115 patients from 2017 to 2020 were retrospectively retrieved. Of these, 6154 (87.9%) studies were Visualization A (No or minimal limitations), 709 (10.1%) were Visualization B (Moderate limitations), and 135 (1.9%) were Visualization C (Severe limitations). Randomly sampled 90 studies, with 30 studies in each Visualization category, were included for analysis. Nine radiologists (3 senior attendings, 3 junior attendings and 3 body imaging fellows) blinded to the original categorization independently reviewed each study and assigned a Visualization Score. Intraclass correlation coefficient (ICC) was used to quantify inter-reader agreement.
RESULTS: ICC among all 9 radiologists was 0.70 (95% CI 0.63-0.77). ICCs among senior attendings, junior attendings and body imaging fellows were 0.68 (CI 0.58-0.76), 0.72 (CI 0.62-0.80) and 0.76 (CI 0.68-0.83), respectively. Subgroup analysis by liver parenchyma was further performed. ICC was highest in the patient group with normal liver parenchyma (0.69, CI 0.56-0.81), followed by steatosis (0.66, CI 0.54-0.79) and cirrhosis (0.58, CI 0.43-0.73), respectively.
CONCLUSIONS: US LI-RADS Visualization Score is a reliable tool with good inter-reader agreement that can be used to indicate the expected level of sensitivity of a screening and surveillance ultrasound examination for detecting focal liver observations.
引用
- Tiyarattanachai T, Bird KN, Lo EC, et al. Ultrasound Liver Imaging Reporting and Data System (US LI-RADS) Visualization Score: a reliability analysis on inter-reader agreement. Abdom Radiol (NY). 2021. PMID: 34228197. doi:10.1007/s00261-021-03067-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。