低剂量CT联合基于模型的迭代重建算法在肿瘤患者随访中的应用:剂量降低与图像质量
125例肿瘤患者接受100 kV低剂量与120 kV标准剂量增强CT,比较基于模型迭代重建(MBIR)与混合迭代重建(HIR)的图像质量和辐射剂量。MBIR组图像质量中位评分4分高于HIR组3分(p=0.017),噪声更低、SNR和CNR更高(均p<0.001),辐射剂量显著更低(p<0.001)。
要点
- 肿瘤随访CT采用MBIR联合低kV方案,辐射剂量显著低于HIR(p<0.001)。
- MBIR图像质量中位评分4分(范围3-4)高于HIR 3分(3-4),p=0.017。
- MBIR图像噪声(SD)更低,SNR和CNR在各解剖区域均更高(均p<0.001)。
核心结论
- MBIR联合低kV设置可在全身CT成像中实现重要剂量降低,并在定性和定量上获得更好的图像质量。
研究设计与样本
- 125例肿瘤患者接受100 kV低剂量和120 kV标准剂量增强CT,比较MBIR与HIR重建图像,采用4点Likert量表评估图像质量。
关键影像表现/征象
- MBIR图像质量总体中位评分4分(范围3-4),HIR为3分(3-4),p=0.017。
- 所有解剖区域MBIR的CT衰减值显著高于HIR、SD显著低于HIR(均p<0.001)。
- 所有区域MBIR的SNR和CNR均显著高于HIR(均p<0.001)。
诊断标准与关键数值
- 图像质量采用4点Likert量表评估,MBIR中位4分(范围3-4)vs HIR 3分(3-4),p=0.017。
- CT衰减值在肝、脾、椎旁肌、主动脉腔和皮下脂肪的ROI内记录,单位HU。
- 图像噪声以SD表示,并计算SNR和CNR。
临床应用与阅片要点
- 肿瘤患者随访全身CT可采用MBIR联合低kV方案,以降低辐射剂量并维持高图像质量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare image quality and radiation dose of CT images reconstructed with model-based iterative reconstruction (MBIR) and hybrid-iterative (HIR) algorithm in oncologic patients.
METHODS: 125 oncologic patients underwent both contrast-enhanced low- (100 kV), and standard (120 kV) dose CT, were enrolled. Image quality was assessed by using a 4-point Likert scale. CT attenuation values, expressed in Hounsfield unit (HU), were recorded within a regions of interest (ROI) of liver, spleen, paraspinal muscle, aortic lumen, and subcutaneous fat tissue. Image noise, expressed as standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Radiation dose were analyzed. Paired Student's t-test was used to compare all continuous variables.
RESULTS: The overall median score assessed as image quality for CT images with the MBIR algorithm was significantly higher in comparison with HIR [4 (range 3-4) vs 3 (3-4), p = 0.017].CT attenuation values and SD were significantly higher and lower, respectively, in all anatomic districts in images reconstructed with MBIR in comparison with HIR ones (all p < 0.001). SNR and CNR values were higher in CT images reconstructed with MBIR, reaching a significant difference in all districts (all p < 0.001). Radiation dose were significantly lower in the MBIR group compared with the HIR group (p < 0.001).
CONCLUSIONS: MBIR combined with low-kV setting allows an important dose reduction in whole-body CT imaging, reaching a better image quality both qualitatively and quantitatively.
ADVANCES IN KNOWLEDGE: MBIR with low-dose approach allows a reduction of dose exposure, maintaining high image quality, especially in patients which deserve a longlasting follow-up.