无个体化调整的高螺距冠状动脉CT血管成像在TAVI术前评估中的诊断效能
该研究纳入100例TAVI术前患者,采用前瞻性心电触发高螺距CT冠脉成像,以有创冠脉造影为参考标准,评估冠脉狭窄的诊断效能。结果显示仅30.3%的节段达到诊断图像质量,敏感度75%、特异度80.5%,阴性预测值高达98.5%,但阳性预测值仅16%,提示该方法在高心率及钙化患者中排除狭窄价值较高,但阳性发现需谨慎。
要点
- 高螺距CT在TAVI术前患者中仅30.3%的冠脉节段达到诊断图像质量。
- 该方法阴性预测值高达98.5%,但阳性预测值仅16%,阳性结果需进一步验证。
- 仅3例患者所有冠脉节段均可完全排除显著狭窄,运动伪影是主要限制。
关键影像表现/征象
- 2例患者检出冠状动脉异常。
- 仅30.3%的节段达到诊断图像质量(评分1-3分)。
- 仅3例患者所有节段均可完全排除显著冠状动脉狭窄。
- 运动伪影普遍存在,仅少数研究完全无运动伪影。
诊断标准与关键数值
- 显著冠状动脉狭窄定义为直径狭窄≥50%,由一名观察者评估,三分之一的患者由两名观察者独立评估。
- 以有创冠状动脉造影为参考标准,敏感度75%、特异度80.5%、阳性预测值16%、阴性预测值98.5%。
- 图像质量采用四点量表(0-3分)评估。
- 两名观察者按患者评估的间一致性极好(kappa=1)。
临床应用与阅片要点
- 在高螺距TAVI术前CT中,若冠脉节段图像质量良好且阴性,可高置信度排除显著狭窄(NPV 98.5%)。
- 阳性发现(狭窄≥50%)因PPV仅16%,需结合临床及有创冠脉造影进一步确认。
- 需注意高心率及严重钙化对图像质量的影响,报告时应描述可评估节段范围及运动伪影。
局限性
- 单中心研究,样本量有限(100例)。
- 仅三分之一的患者由两名观察者独立评估,观察者间一致性数据不完整。
- 高螺距模式在TAVI人群(高心率、冠脉钙化)中图像质量有限,仅30.3%节段可诊断。
- 阳性预测值低,阳性结果可靠性不足。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the ability to assess the coronary arteries using pre-procedural computed tomography (CT; high-pitch mode) in patients referred for transcatheter aortic valve implantation (TAVI).
METHODS AND MATERIALS: CT and invasive coronary angiography (ICA) were performed pre-TAVI in 100 patients (46 women; 79 ± 5.9 years). CT was performed in prospectively ECG-triggered high-pitch mode after intravenous administration of 70 ml iodinated contrast medium. Image quality was assessed using a four-point scale (graded 0-3). Significant coronary artery stenosis (≥50% diameter) was graded as either present or absent by one observer and in one-third of patients by two observers independently. ICA was the standard of reference. Results were reported per segment and per patient.
RESULTS: Twenty-two percent of patients had known coronary artery disease (CAD). In two cases, a coronary anomaly was detected. Diagnostic image quality (grade 1-3) was achieved in 30.3% of segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 75%, 80.5%, 16%, and 98.5%, respectively. Significant coronary stenosis could be ruled out completely in all segments in three patients. The interrater agreement per patient was excellent (kappa = 1).
CONCLUSION: Relevant coronary findings can frequently be observed in high-pitch TAVI-planning CT. Despite the limitations of the technique and in patients referred to pre-TAVI evaluation (rapid heart rate, coronary calcifications, etc.), a valid evaluation of coronary arteries is possible in a considerable proportion of segments with a high NPV; however, few studies were completely free of motion artefacts to dependably exclude CAD using this technique in this challenging group of patients.
引用
- Seitz P, Krieghoff C, Gottschling S, et al. Pre-procedural high-pitch coronary CT angiography assessment of patients undergoing transcatheter aortic valve implantation (TAVI) without patient-specific adjustment: analysis of diagnostic performance. Clin Radiol. 2021. PMID: 34261598. doi:10.1016/j.crad.2021.06.008