文献速递心血管CT

CT测量的二尖瓣环形状与TAVR术后二尖瓣反流的关系

The Relationship of Mitral Annulus Shape at CT to Mitral Regurgitation after Transcatheter Aortic Valve Replacement.
PubMed 文献 · Radiology · 2021-07-27

这项回顾性队列研究纳入104例接受TAVR的中重度二尖瓣反流患者,利用多层螺旋CT构建简化的D形二尖瓣环模型,评估二尖瓣环尺寸与钙化。结果显示79例患者术后二尖瓣反流改善,最大改善出现在术后第1年。D形瓣环周长和原发性二尖瓣反流是TAVR术后二尖瓣反流改善较少的独立预测因素。

要点

  • TAVR术前中重度二尖瓣反流患者中,约四分之三术后反流改善,最大改善在术后1年。
  • CT测量的D形二尖瓣环周长增大与术后二尖瓣反流改善较少独立相关。
  • 原发性二尖瓣反流是TAVR术后二尖瓣反流改善较少的独立预测因素。

局限性

  • 回顾性研究设计。
  • 单中心研究。
  • 仅纳入104例中重度二尖瓣反流患者,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background There are conflicting results over the improvement rate and predictors of mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR). Purpose To define the cause, degree of improvement, and improvement predictors of moderate to severe mitral regurgitation in patients undergoing TAVR by using a simplified D-shaped mitral annulus model derived from multisection CT (MSCT). Materials and Methods This retrospective cohort study included 528 consecutive patients who underwent TAVR between April 2012 and October 2019. Patients with previous surgical aortic valve replacement and those with moderate or severe mitral stenosis were excluded. A total of 104 patients with moderate to severe mitral regurgitation met the inclusion criteria and were included in the final analysis. At least one grade reduction in the severity of mitral regurgitation was considered indicative of mitral regurgitation improvement after TAVR. Up to 5-year post-TAVR follow-up of mitral regurgitation improvement was evaluated. Mitral annular dimensions (annular area, circumference, and trigone-to-trigone, intercommissural, and anteroposterior distances) and annular calcification were assessed at MSCT with use of dedicated postprocessing software. Associations with mitral regurgitation improvement after TAVR were explored. Results A total of 104 patients with concomitant mitral regurgitation who underwent TAVR (mean age, 74 years ± 7; 61 men) were included in the study. Mitral regurgitation improved in 79 patients after TAVR and remained unchanged in the remaining 25 patients. Maximum improvement was observed in the 1st year after TAVR. D-shaped mitral annular parameters, including annular circumference (odds ratio [OR], 1.05; 95% CI: 1.01, 1.1; P = .02) and trigone-to-trigone (OR, 1.2; 95% CI: 1.03, 1.39; P = .02) and intercommissural (OR, 1.15; 95% CI: 1.02, 1.31; P = .02) distances, were related to mitral regurgitation improvement. In addition, patients with coronary artery disease had greater improvement in mitral regurgitation after TAVR (OR, 0.17; 95% CI: 0.04, 0.76; P = .02). Primary mitral regurgitation (OR, 5.1; 95% CI: 1.1, 24; P = .04) and D-shaped annular circumference (OR, 1.06; 95% CI: 1, 1.11; P = .04) were independent predictors of less mitral regurgitation improvement after TAVR. Conclusion Concomitant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) tends to improve after the procedure, with maximum improvement in the 1st year after TAVR. D-shaped annular circumference and primary mitral regurgitation were independent predictors of less mitral regurgitation improvement after TAVR. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Collins in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Li X, Hagar A, Wei X, et al. The Relationship of Mitral Annulus Shape at CT to Mitral Regurgitation after Transcatheter Aortic Valve Replacement. Radiology. 2021. PMID: 34313471. doi:10.1148/radiol.2021210267

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。