文献速递心血管CT

CAD-RADS 在大型学术医疗中心的采纳趋势分析

Coronary Artery Disease Reporting and Data System (CAD-RADS) Adoption: Analysis of Local Trends in a Large Academic Medical Center.
PubMed 文献 · Radiol Cardiothorac Imaging · 2021-06-24

该研究回顾性分析了一家高流量心脏 CT 中心 2017 至 2020 年间 6562 份冠状动脉 CTA 报告,CAD-RADS 采纳率达 95%,仅 5% 未使用。未使用病例中 58% 为主动退出、42% 为例外情况,退出多因复杂病变(更高狭窄程度、支架、CABG),但退出率随时间下降。

要点

  • CAD-RADS 采纳率高(95%),但复杂病例(支架、CABG、更高狭窄)更易被主动退出。
  • 主动退出率在首年逐季度下降后趋于稳定,支架和 CABG 患者的退出率随时间持续降低。
  • 例外情况最常见为冠状动脉夹层(44%)和冠状动脉起源异常(41%)。

核心结论

  • CAD-RADS 在该中心被快速广泛采纳,报告率 95%(6264/6562)。
  • 阅片者更多在复杂 CAD 病例(更高狭窄程度、支架、CABG)中主动退出 CAD-RADS。
  • 主动退出率随时间下降,尤其支架和 CABG 患者;例外情况以冠状动脉夹层和起源异常最常见。

研究设计与样本

  • 单中心回顾性研究,纳入 2017 年 1 月 1 日至 2020 年 2 月 13 日共 6562 份冠状动脉 CTA 报告。
  • 未使用 CAD-RADS 的报告被分类为主动退出(opt-outs)或例外(exceptions)。
  • 对主动退出病例回顾性分配 CAD-RADS 分类,并记录冠状动脉 CTA 临床指征。

诊断标准与关键数值

  • CAD-RADS 报告率为 95%(6264/6562)。
  • 未使用 CAD-RADS 的 5%(n=298)中,主动退出占 58%(n=172),例外占 42%(n=126)。
  • 更高狭窄程度、支架和 CABG 与主动退出相关(OR 8.3,95%CI 1.6–42.1;P<.001)。
  • 首年主动退出率逐季度下降(OR 0.77,95%CI 0.61–0.96;P=.01),之后稳定。
  • 支架患者主动退出率随时间下降(OR 0.82,95%CI 0.73–0.92;P=.008),CABG 患者亦下降(OR 0.83,95%CI 0.76–0.91;P<.001)。

临床应用与阅片要点

  • 在复杂 CAD(支架、CABG、更高狭窄程度)病例中,阅片者可能主动退出 CAD-RADS,报告时应留意分类的一致性。
  • 冠状动脉夹层和起源异常是 CAD-RADS 最常见的例外,遇到时可不强制分类但仍建议描述。
  • 随时间推移主动退出率下降,提示培训或经验积累可能提高 CAD-RADS 在复杂病例中的适用性。

局限性

  • 单中心回顾性研究,结果外推需谨慎。
  • 主动退出病例的 CAD-RADS 分类为回顾性分配,可能存在分类偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To perform a retrospective review of Coronary Artery Disease Reporting and Data System (CAD-RADS) adoption at a high-volume cardiac CT service.

MATERIALS AND METHODS: In this retrospective study, the adoption of CAD-RADS in 6562 coronary CT angiography (CTA) reports from January 1, 2017, to February 13, 2020, was evaluated. Reports without CAD-RADS were classified as opt-outs or exceptions to CAD-RADS. CAD-RADS classifications were retrospectively assigned to the opt-outs and the clinical indications for coronary CTA.

RESULTS: CAD-RADS scores were reported in 95% (6264 of 6562) of cases. Among the 5% (n = 298) of reports not reported according to CAD-RADS, 58% (n = 172) were considered opt-outs and 42% (n = 126) were exceptions. Cases with higher degree of stenosis, stents, and coronary artery bypass grafts (CABGs) occurred more often in opt-outs versus reports with CAD-RADS (odds ratio [OR], 8.3 [95% CI: 1.6, 42.1]; P < .001). The quarterly opt-out rate decreased over consecutive quarters in the 1st year (OR, 0.77 [95% CI: 0.61, 0.96]; P = .01), then stabilized. Quarterly opt-out rate for patients with stents decreased over time (OR, 0.82 [95% CI: 0.73, 0.92]; P = .008), as did the opt-out rates in patients with CABG (OR, 0.83 [95% CI: 0.76, 0.91]; P < .001). Exceptions (n = 126) included coronary dissections (44%), anomalous coronary arteries (41%), coronary artery aneurysms or pseudoaneurysms (10%), vasculitis (2%), stent complications (2%), and extrinsic compression of grafts (2%).

CONCLUSION: CAD-RADS was adopted rapidly and widely. Readers opted out of its use most often in complex cases of CAD, and the most common exceptions were coronary dissections and anomalous coronary artery.Keywords: Coronary Arteries, CT Angiography© RSNA, 2021.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Takigami AK, Thondapu V, Goiffon RJ, et al. Coronary Artery Disease Reporting and Data System (CAD-RADS) Adoption: Analysis of Local Trends in a Large Academic Medical Center. Radiol Cardiothorac Imaging. 2021. PMID: 34235445. doi:10.1148/ryct.2021210016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。