基于残差深度学习的去噪加速肥胖受试者体内心脏扩散张量MRI

Accelerated in Vivo Cardiac Diffusion-Tensor MRI Using Residual Deep Learning-based Denoising in Participants with Obesity.
PubMed 文献 · Radiol Cardiothorac Imaging · 2021-06-24

本研究开发残差深度学习去噪算法(DnCNN)加速体内心脏扩散张量MRI(DT-MRI),在26名参与者(含6名肥胖者)中比较不同平均次数结合DnCNN与参考8次平均的图像质量和DT-MRI参数。结果显示4次平均结合DnCNN在SNR、SSIM、MD、FA、HAT上与参考无差异,且保留肥胖相关差异,表明可至少加速2倍。

要点

  • 4次平均结合DnCNN与参考8次平均图像质量和DT-MRI参数无差异。
  • 2次平均结合DnCNN可保留肥胖者MD升高、FA和HAT降低的关系。
  • 未使用DnCNN的4次或2次平均则无法保留该关系。

局限性

  • 样本量较小(26名参与者,其中肥胖者仅6名)。
  • 单中心前瞻性研究,需外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and assess a residual deep learning algorithm to accelerate in vivo cardiac diffusion-tensor MRI (DT-MRI) by reducing the number of averages while preserving image quality and DT-MRI parameters.

MATERIALS AND METHODS: In this prospective study, a denoising convolutional neural network (DnCNN) for DT-MRI was developed; a total of 26 participants, including 20 without obesity (body mass index [BMI] < 30 kg/m2; mean age, 28 years ± 3 [standard deviation]; 11 women) and six with obesity (BMI ≥ 30 kg/m2; mean age, 48 years ± 11; five women), were recruited from June 19, 2019, to July 29, 2020. DT-MRI data were constructed at four averages (4Av), two averages (2Av), and one average (1Av) without and with the application of the DnCNN (4AvDnCNN, 2AvDnCNN, 1AvDnCNN). All data were compared against the reference DT-MRI data constructed at eight averages (8Av). Image quality, characterized by using the signal-to-noise ratio (SNR) and structural similarity index (SSIM), and the DT-MRI parameters of mean diffusivity (MD), fractional anisotropy (FA), and helix angle transmurality (HAT) were quantified.

RESULTS: No differences were found in image quality or DT-MRI parameters between the accelerated 4AvDnCNN DT-MRI and the reference 8Av DT-MRI data for the SNR (29.1 ± 2.7 vs 30.5 ± 2.9), SSIM (0.97 ± 0.01), MD (1.3 µm2/msec ± 0.1 vs 1.31 µm2/msec ± 0.11), FA (0.32 ± 0.05 vs 0.30 ± 0.04), or HAT (1.10°/% ± 0.13 vs 1.11°/% ± 0.09). The relationship of a higher MD and lower FA and HAT in individuals with obesity compared with individuals without obesity in reference 8Av DT-MRI measurements was retained in 4AvDnCNN and 2AvDnCNN DT-MRI measurements but was not retained in 4Av or 2Av DT-MRI measurements.

CONCLUSION: Cardiac DT-MRI can be performed at an at least twofold-accelerated rate by using DnCNN to preserve image quality and DT-MRI parameter quantification.Keywords: Adults, Cardiac, Obesity, Technology Assessment, MR-Diffusion Tensor Imaging, Heart, Tissue CharacterizationSupplemental material is available for this article.© RSNA, 2021.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。