心血管磁共振诊断心脏移植排斥反应准确性的Meta分析
该Meta分析纳入10项研究共564例患者,以心内膜心肌活检为参考标准,评估多种CMR参数对急性心脏移植排斥反应的诊断效能。结果显示T2 mapping诊断准确性最高(AUC 0.92),其次为native T1(AUC 0.84)和ECV(AUC 0.78),LGE诊断性能差(AUC 0.56)。
要点
- T2 mapping诊断急性排斥反应AUC最高(0.92),敏感度86.5%、特异度85.9%。
- native T1敏感度高(84.6%)但特异度较低(70.1%),ECV特异度更低(67.6%)。
- LGE诊断性能差(AUC 0.56),不推荐单独用于排斥反应检测。
局限性
- 纳入研究数量较少(10项),样本量有限(564例)。
- Meta分析为回顾性汇总,可能存在异质性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this meta-analysis was to assess the diagnostic performance of various CMR imaging parameters for evaluating acute cardiac transplant rejection.
BACKGROUND: Endomyocardial biopsy is the current gold standard for detection of acute cardiac transplant rejection. Cardiac magnetic resonance (CMR) is uniquely capable of myocardial tissue characterization and may be useful as a noninvasive alternative for the diagnosis of graft rejection.
METHODS: PubMed and Web of Science were searched for relevant publications reporting on the use of CMR myocardial tissue characterization for detection of acute cardiac transplant rejection with endomyocardial biopsy as the reference standard. Pooled sensitivity, specificity, and hierarchical modeling-based summary receiver-operating characteristic curves were calculated.
RESULTS: Of 478 papers, 10 studies comprising 564 patients were included. The sensitivity and specificity for the detection of acute cardiac transplant rejection were 84.6 (95% CI: 65.6-94.0) and 70.1 (95% CI: 54.2-82.2) for T1, 86.5 (95% CI: 72.1-94.1) and 85.9 (95% CI: 65.2-94.6) for T2, 91.3 (95% CI: 63.9-98.4) and 67.6 (95% CI: 56.1-77.4) for extracellular volume fraction (ECV), and 50.1 (95% CI: 31.2-68.9) and 60.2 (95% CI: 36.7-79.7) for late gadolinium enhancement (LGE). The areas under the hierarchical modeling-based summary receiver-operating characteristic curve were 0.84 (95% CI: 0.81-0.87) for T1, 0.92 (95% CI: 0.89-94) for T2, 0.78 (95% CI: 0.74-0.81) for ECV, and 0.56 (95% CI: 0.51-0.60) for LGE. T2 values demonstrated the highest diagnostic accuracy, followed by native T1, ECV, and LGE (all P values <0.001 for T1, ECV, and LGE vs T2).
CONCLUSIONS: T2 mapping demonstrated higher diagnostic accuracy than other CMR techniques. Native T1 and ECV provide high diagnostic use but lower diagnostic accuracy compared with T2, which was related primarily to lower specificity. LGE showed poor diagnostic performance for detection of rejection.