早产年轻成人的四维血流MRI右心室充盈改变
该研究为前瞻性研究的二次分析,用心脏4D flow MRI比较35名中重度早产与21名足月年轻成人的心室内血流。早产组成人右心室E/A动能比和E/A峰值充盈率比降低,收缩期、舒张晚期及全周期黏性能量耗散增加,提示右心室舒张充盈改变。
要点
- 早产年轻成人右心室E/A动能比及E/A峰值充盈率比低于足月成人。
- 早产组右心室收缩期、舒张晚期及全周期黏性能量耗散增高。
- 4D flow MRI可用于评估早产人群右心室舒张功能改变。
核心结论
- 中重度早产年轻成人存在右心室舒张充盈改变,可能与其心力衰竭风险增加相关。
研究设计与样本
- 前瞻性研究的二次分析,2016至2020年纳入56名年轻成人,其中35名中重度早产(出生体重<1500g或胎龄≤32周)和21名足月。
- 所有参与者接受心脏MRI,包括电影序列评估心脏结构与功能以及4D flow MRI。
诊断标准与关键数值
- 早产组右心室E/A动能比为2.4±1.7,足月组为3.5±1.4(P<.01)。
- 早产组右心室E/A峰值充盈率比为2.3±1.3,足月组为3.5±2.5(P=.03)。
- 早产组收缩期黏性能量耗散为5.7±3.0 µW/mL,足月组为4.2±1.6 µW/mL(P=.03)。
- 早产组舒张晚期黏性能量耗散为3.9±4.0 µW/mL,足月组为2.2±1.6 µW/mL(P=.03)。
- 早产组全心动周期黏性能量耗散为2.4±1.0 µJ/mL,足月组为1.9±0.6 µJ/mL(P=.02)。
临床应用与阅片要点
- 阅片时可关注右心室E/A动能比及峰值充盈率比,早产年轻成人可能显示E/A比值降低。
- 黏性能量耗散增高可提示右心室舒张充盈效率下降,需结合临床背景解读。
局限性
- 本研究为二次分析,样本量较小(56例),仅纳入中重度早产年轻成人,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To use four-dimensional (4D) flow MRI to measure intraventricular flow in young adults who were born prematurely to investigate mechanisms that may account for increased heart failure risk in this population.
MATERIALS AND METHODS: In this secondary analysis of a prospective study, a total of 56 young adults participated in an observational cardiac 4D flow MRI study from 2016 to 2020. There were 35 participants who had been born moderately to extremely prematurely (birth weight <1500 g or gestational age ≤32 weeks; 23 women; mean age, 26 years ± 4) and 21 term-born participants (11 women; mean age, 25 years ± 3). Participants underwent cardiac MRI, including cine cardiac structure and function assessment, as well as 4D flow MRI. In each ventricle, normalized kinetic energy (KE/end diastolic volume) and flow through the atrioventricular valve were computed and compared between term-born and preterm participants at systolic and diastolic (early diastolic filling rate [E wave] and late diastolic filling [atrial contraction] rate [A wave]) time points by using Wilcoxon rank-sum tests.
RESULTS: Preterm-born participants had lower right ventricular (RV) E wave/A wave (E/A) KE ratios (2.4 ± 1.7 vs 3.5 ± 1.4; P <.01) and lower E/A peak filling rate ratios (computed from RV volume-time curves; 2.3 ± 1.3 vs 3.5 ± 2.5; P = .03). Additionally, viscous energy dissipation was increased during systole (5.7 µW/mL ± 3.0 vs 4.2 µW/mL ± 1.6; P = .03), increased during late diastole (3.9 µW/mL ± 4.0 vs 2.2 µW/mL ± 1.6; P = .03), and summed over the cardiac cycle (2.4 µJ/mL ± 1.0 vs 1.9 µJ/mL ± 0.6; P = .02) in preterm relative to term participants.
CONCLUSION: These results suggest that RV diastolic filling is altered in young adults who were born moderately to severely prematurely.Supplemental material is available for this article. Keywords: Adults, Cardiac, Comparative Studies, MR-Imaging, Right Ventricle © RSNA, 2021.
引用
- Corrado PA, Barton GP, Macdonald JA, et al. Altered Right Ventricular Filling at Four-dimensional Flow MRI in Young Adults Born Prematurely. Radiol Cardiothorac Imaging. 2021. PMID: 34250493. doi:10.1148/ryct.2021200618
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。