文献速递心血管SPECT

可解释人工智能SPECT诊断冠心病的临床部署

Clinical Deployment of Explainable Artificial Intelligence of SPECT for Diagnosis of Coronary Artery Disease.
PubMed 文献 · JACC Cardiovasc Imaging · 2021-07-14

本研究开发并评估了一种可解释深度学习模型CAD-DL,用于SPECT心肌灌注显像后检测阻塞性冠心病。在9中心3578例患者中,CAD-DL的AUC在重复测试为0.83,外部测试为0.80,均显著高于自动定量TPD和读者诊断。模型可集成于标准临床工作站,结果生成迅速。

要点

  • CAD-DL基于负荷灌注、室壁运动和增厚图及左室容积、年龄、性别计算阻塞性CAD概率。
  • CAD-DL在重复测试和外部测试中AUC均高于应力TPD和读者诊断。
  • 模型高亮贡献心肌区域以解释预测,并可在标准工作站快速生成结果。

局限性

  • 原文未明确报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Explainable artificial intelligence (AI) can be integrated within standard clinical software to facilitate the acceptance of the diagnostic findings during clinical interpretation.

OBJECTIVES: This study sought to develop and evaluate a novel, general purpose, explainable deep learning model (coronary artery disease-deep learning [CAD-DL]) for the detection of obstructive CAD following single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI).

METHODS: A total of 3,578 patients with suspected CAD undergoing SPECT MPI and invasive coronary angiography within a 6-month interval from 9 centers were studied. CAD-DL computes the probability of obstructive CAD from stress myocardial perfusion, wall motion, and wall thickening maps, as well as left ventricular volumes, age, and sex. Myocardial regions contributing to the CAD-DL prediction are highlighted to explain the findings to the physician. A clinical prototype was integrated using a standard clinical workstation. Diagnostic performance by CAD-DL was compared to automated quantitative total perfusion deficit (TPD) and reader diagnosis.

RESULTS: In total, 2,247 patients (63%) had obstructive CAD. In 10-fold repeated testing, the area under the receiver-operating characteristic curve (AUC) (95% CI) was higher according to CAD-DL (AUC: 0.83 [95% CI: 0.82-0.85]) than stress TPD (AUC: 0.78 [95% CI: 0.77-0.80]) or reader diagnosis (AUC: 0.71 [95% CI: 0.69-0.72]; P < 0.0001 for both). In external testing, the AUC in 555 patients was higher according to CAD-DL (AUC: 0.80 [95% CI: 0.76-0.84]) than stress TPD (AUC: 0.73 [95% CI: 0.69-0.77]) or reader diagnosis (AUC: 0.65 [95% CI: 0.61-0.69]; P < 0.001 for all). The present model can be integrated within standard clinical software and generates results rapidly (<12 seconds on a standard clinical workstation) and therefore could readily be incorporated into a typical clinical workflow.

CONCLUSIONS: The deep-learning model significantly surpasses the diagnostic accuracy of standard quantitative analysis and clinical visual reading for MPI. Explainable artificial intelligence can be integrated within standard clinical software to facilitate acceptance of artificial intelligence diagnosis of CAD following MPI.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。