文献速递胸部儿科影像CT

0.3毫希沃特CT与标准剂量CT在儿童及年轻癌症患者肺结节检出中的比较

Comparison of 0.3-mSv CT to Standard-Dose CT for Detection of Lung Nodules in Children and Young Adults With Cancer.
PubMed 文献 · AJR Am J Roentgenol · 2021-07-07

这项前瞻性研究纳入78例4-21岁已知或疑似恶性肿瘤的儿童及年轻患者,在同一检查中额外行降低剂量胸部CT(平均有效剂量0.3毫希沃特,较临床CT的1.8毫希沃特降低83%)。三位独立放射科医师盲法阅片,以临床CT为参考标准,降低剂量CT检出92%的肺结节,敏感度63%-77%、特异度80%-90%,观察者间存在结节一致性中等(κ=0.53 vs 0.54)。

要点

  • 降低剂量CT(平均0.3毫希沃特)可显示92%的肺结节,敏感度63%-77%、特异度80%-90%。
  • 降低剂量CT与临床CT的结节存在一致性中等至相当(κ=0.45-0.67),结节数目和大小一致性良好至优秀。
  • 假阴性病例在临床CT上结节中位数为1个。

核心结论

  • 降低剂量CT可显示儿童及年轻癌症患者90%以上的肺结节,阅片者检出结节的敏感度中等、特异度高;平均有效剂量0.3毫希沃特的CT具有可接受的诊断性能,有潜力降低患者剂量或扩大CT应用(例如在筛查或监测方案中替代X线摄影)。

研究设计与样本

  • 前瞻性研究,纳入78例4-21岁已知或疑似恶性肿瘤、接受临床指示胸部CT的患者,在同一检查中额外行降低剂量胸部CT;分离去标识化的CT检查由三位独立放射科医师盲法阅片,其中一位阅片者进行二次复核以匹配标准剂量与降低剂量检查间的结节;以临床检查为参考标准计算降低剂量检查的诊断性能;用Cohen kappa计算观察者内和观察者间一致性;临床试验注册号NCT03681873。

关键影像表现/征象

  • 临床CT上45/78例(58%)患者共检出162个肺结节,平均大小3.4±3.3毫米。
  • 降低剂量CT上可见92%的结节。
  • 假阴性降低剂量CT检查的患者中,临床CT上结节中位数为1个。

诊断标准与关键数值

  • 降低剂量CT检出结节的敏感度在三位阅片者间为63%-77%,特异度为80%-90%。
  • 临床CT与降低剂量CT的观察者内一致性:结节存在κ=0.45-0.67(中等至相当),结节数目κ=0.68-0.84(良好至优秀),结节大小κ=0.69-0.86(良好至优秀)。
  • 观察者间一致性:结节存在降低剂量CT κ=0.53、临床CT κ=0.54(均为中等)。
  • 平均估计有效剂量:临床CT 1.8±1.1毫希沃特,降低剂量CT 0.3±0.1毫希沃特,降低83%。

临床应用与阅片要点

  • 作者指出,平均有效剂量0.3毫希沃特的CT对儿童及年轻患者肺结节检测具有可接受的诊断性能,有潜力降低患者剂量或扩大CT应用(例如在筛查或监测方案中替代X线摄影)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. CT is the imaging modality of choice to identify lung metastasis. OBJECTIVE. The purpose of this study was to evaluate the performance of reduced-dose CT for the detection of lung nodules in children and young adults with cancer. METHODS. This prospective study enrolled patients 4-21 years old with known or suspected malignancy who were undergoing clinically indicated chest CT. Study participants underwent an additional investigational reduced-dose chest CT examination in the same imaging encounter. Separated deidentified CT examinations were reviewed in blinded fashion by three independent radiologists. One reviewer performed a subsequent secondary review to match nodules between the standard- and reduced-dose examinations. Diagnostic performance was computed for the reduced-dose examinations using the clinical examinations as the reference standard. Intraobserver agreement and interobserver agreement were calculated using Cohen kappa. RESULTS. A total of 78 patients (44 male patients and 34 female patients; mean age, 15.2 ± 3.8 [SD] years) were enrolled. The mean estimated effective dose was 1.8 ± 1.1 mSv for clinical CT and 0.3 ± 0.1 mSv for reduced-dose CT, which is an 83% dose reduction. Forty-five of the 78 (58%) patients had 162 total lung nodules (mean size, 3.4 ± 3.3 mm) detected on the clinical CT examinations. A total of 92% of nodules were visible on reduced-dose CT. The sensitivity and specificity of reduced-dose CT for nodules ranged from 63% to 77% and from 80% to 90%, respectively, across the three reviewers. Intraob-server agreement between clinical CT and reduced-dose CT was moderate to substantial for the presence of nodules (κ = 0.45-0.67) and was good to excellent for the number of nodules (κ = 0.68-0.84) and nodule size (κ = 0.69-0.86). Interobserver agreement for the presence of nodules was moderate for both reduced-dose (κ = 0.53) and clinical (κ = 0.54) CT. A median of one nodule was present on clinical CT in patients with a falsely negative reduced-dose CT examination. CONCLUSION. Reduced-dose CT depicts more than 90% of lung nodules in children and young adults with cancer. Reviewers identified the presence of nodules with moderate sensitivity and high specificity. CLINICAL IMPACT. CT performed at a 0.3-mSv mean effective dose has acceptable diagnostic performance for lung nodule detection in children and young adults and has the potential to reduce patient dose or expand CT utilization (e.g., to replace radiography in screening or monitoring protocols). TRIAL REGISTRATION. ClinicalTrials.gov NCT03681873.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Thapaliya S, Gilligan LA, Brady SL, et al. Comparison of 0.3-mSv CT to Standard-Dose CT for Detection of Lung Nodules in Children and Young Adults With Cancer. AJR Am J Roentgenol. 2021. PMID: 34232694. doi:10.2214/AJR.21.26183

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。