文献速递妇产影像儿科影像US

胎儿胸围与肺容积及其与胎儿大小和肺动脉血流的关系

Fetal Thoracic Circumference and Lung Volume and Their Relation to Fetal Size and Pulmonary Artery Blood Flow.
PubMed 文献 · J Ultrasound Med · 2021-07-21

本研究对447例孕30周单胎妊娠进行横断面超声评估,测量胎儿胸围、肺容积、头围、腹围及股骨长,并行肺动脉近端分支多普勒血流速度测定。胸围和肺容积与胎儿大小指标呈中至低度相关,其中与腹围相关性最强(r=0.64),与股骨长相关性最低(r=0.28);校正孕龄、母亲尼古丁使用、孕前体重指数及胎儿性别后对腹围关联影响轻微。胸围和肺容积与肺动脉血流速度指标相关性弱(r≤0.17)。

要点

  • 孕30周时胸围、肺容积与胎儿大小呈中至低度相关,与腹围相关性最强(r=0.64)。
  • 胸围和肺容积与肺动脉血流速度指标仅呈弱相关(r≤0.17)。
  • 校正孕龄、母亲尼古丁使用、孕前体重指数及胎儿性别后,与腹围的关联影响轻微。

核心结论

  • 孕30周时胸围和肺容积与胎儿大小呈中至低度相关,与腹围关系最密切;胸围和肺容积与肺动脉血流速度指标相关性低。

研究设计与样本

  • 横断面研究,纳入一般人群单胎妊娠447例,于孕30周行超声测量胎儿胸围、肺容积、头围、腹围及股骨长,并获取肺动脉近端分支多普勒血流速度指标;采用Pearson相关及多元线性回归分析变量间关联。

诊断标准与关键数值

  • 胸围与腹围相关系数r=0.64,为胸围与胎儿大小指标中最强相关。
  • 肺容积与股骨长相关系数r=0.28,为肺容积与胎儿大小指标中最弱相关。
  • 胸围和肺容积与肺动脉血流速度指标的相关系数r≤0.17。

临床应用与阅片要点

  • 孕30周超声评估胎儿胸围和肺容积时,应结合胎儿大小指标(尤其腹围)综合解读。
  • 胸围和肺容积与肺动脉血流速度指标相关性弱,不宜仅凭胸围或肺容积推断肺动脉血流速度变化。
  • 校正孕龄、母亲尼古丁使用、孕前体重指数及胎儿性别后,胸围和肺容积与腹围的关联影响轻微。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Research on early origins of lung disease suggests the need for studying the relationships of thoracic and lung size with fetal size and pulmonary circulation. The primary aim of this study is therefore to explore the associations between fetal thoracic circumference, lung volume, and fetal size. We also aim to assess if lung volume and thoracic circumference are associated with fetal pulmonary artery blood flow velocity measures.

METHODS: Cross-sectional assessment of singleton pregnancies from the general population (n = 447) at 30 gestational weeks (GW) was performed using ultrasound measurement of fetal thoracic circumference, lung volume, head and abdominal circumference, and femur length. We obtained Doppler blood flow velocity measures from the proximal branches of the fetal pulmonary artery. Associations between variables were studied using Pearson's correlation and multiple linear regression analyses.

RESULTS: Both thoracic circumference and lung volume correlated with fetal size measures, ranging from r = 0.64 between thoracic circumference and abdominal circumference, to r = 0.28 between lung volume and femur length. Adjustment for gestational age, maternal nicotine use, pre-pregnancy body mass index, and fetal sex marginally influenced the associations with abdominal circumference. The correlations of thoracic circumference and lung volume with pulmonary artery blood flow velocity measures were weak (r ≤ 0.17).

CONCLUSION: We found moderate to low correlation between thoracic circumference, lung volume, and fetal size at 30 GW. The closest relationship was with the abdominal circumference. We found low correlations of thoracic circumference and lung volume with pulmonary artery blood flow velocity measures.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hilde K, Lødrup Carlsen KC, Bains KES, et al. Fetal Thoracic Circumference and Lung Volume and Their Relation to Fetal Size and Pulmonary Artery Blood Flow. J Ultrasound Med. 2021. PMID: 34289520. doi:10.1002/jum.15785

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。