非特异性间质性肺炎气体交换异常的超极化129Xe MRI与波谱成像
前瞻性研究纳入36例非特异性间质性肺炎(NSIP)患者与15名健康对照,采用超极化129Xe MRI及波谱评估气体交换功能;NSIP患者屏障摄取升高、红细胞转移缺陷增加,红细胞与屏障峰值比及红细胞化学位移降低。
要点
- NSIP患者129Xe MRI示屏障摄取中位数6.2% vs 健康对照0.53%(P=.003),红细胞转移缺陷中位数20.6% vs 2.8%(P<.001)。
- NSIP患者通气缺陷与健康对照无显著差异(中位数4.4% vs 6.0%,P=.91)。
- NSIP患者波谱红细胞与屏障峰值比中位数0.24 vs 0.57(P<.001),红细胞化学位移中位数217.5 ppm vs 218.2 ppm(P=.001)。
核心结论
- NSIP患者较健康对照屏障摄取增高、红细胞转移减少,波谱示红细胞与屏障峰值比及红细胞化学位移降低。
研究设计与样本
- 前瞻性研究,2017年11月至2020年2月纳入36例NSIP患者(平均年龄57岁±11,27例女性)与15名健康对照(平均年龄39岁±18,2例女性),行超极化129Xe MRI及波谱成像,定量图提供通气、间质屏障摄取及向红细胞 compartment 转移的三维图。
关键影像表现/征象
- NSIP患者屏障摄取中位数6.2%(第一四分位数1.8%,第三四分位数23.9%),健康对照0.53%(第一四分位数0.33%,第三四分位数2.9%)。
- NSIP患者红细胞转移缺陷中位数20.6%(第一四分位数11.6%,第三四分位数27.8%),健康对照2.8%(第一四分位数2.3%,第三四分位数4.9%)。
- NSIP患者通气缺陷中位数4.4%(第一四分位数1.5%,第三四分位数8.7%),健康对照6.0%(第一四分位数2.8%,第三四分位数6.9%)。
- NSIP患者红细胞与屏障峰值比中位数0.24(第一四分位数0.19,第三四分位数0.31),健康对照0.57(第一四分位数0.52,第三四分位数0.67)。
- NSIP患者红细胞化学位移中位数217.5 ppm(第一四分位数217.0 ppm,第三四分位数218.0 ppm),健康对照218.2 ppm(第一四分位数217.9 ppm,第三四分位数218.6 ppm)。
诊断标准与关键数值
- 通气缺陷:NSIP中位数4.4% vs 健康对照6.0%,P=.91,无显著差异。
- 屏障摄取:NSIP中位数6.2% vs 健康对照0.53%,P=.003。
- 红细胞转移缺陷:NSIP中位数20.6% vs 健康对照2.8%,P<.001。
- 红细胞与屏障峰值比:NSIP中位数0.24 vs 健康对照0.57,P<.001。
- 红细胞化学位移:NSIP中位数217.5 ppm vs 健康对照218.2 ppm,P=.001。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Recent studies demonstrate that antifibrotic drugs previously reserved for idiopathic pulmonary fibrosis (IPF) may slow progression in other interstitial lung diseases (ILDs), creating an urgent need for tools that can sensitively assess disease activity, progression, and therapy response across ILDs. Hyperpolarized xenon 129 (129Xe) MRI and spectroscopy have provided noninvasive measurements of regional gas-exchange abnormalities in IPF. Purpose To assess gas exchange function using 129Xe MRI in a group of study participants with nonspecific interstitial pneumonia (NSIP) compared with healthy control participants. Materials and Methods In this prospective study, participants with NSIP and healthy control participants were enrolled between November 2017 and February 2020 and underwent 129Xe MRI and spectroscopy. Quantitative imaging provided three-dimensional maps of ventilation, interstitial barrier uptake, and transfer into the red blood cell (RBC) compartment. Spectroscopy provided parameters of the static RBC and barrier uptake compartments, as well as cardiogenic oscillations in RBC signal amplitude and chemical shift. Differences between NSIP and healthy control participants were assessed using the Wilcoxon rank-sum test. Results Thirty-six participants with NSIP (mean age, 57 years ± 11 [standard deviation]; 27 women) and 15 healthy control participants (mean age, 39 years ± 18; two women) were evaluated. Participants with NSIP had no difference in ventilation compared with healthy control participants (median, 4.4% [first quartile, 1.5%; third quartile, 8.7%] vs 6.0% [first quartile, 2.8%; third quartile, 6.9%]; P = .91), but they had a higher barrier uptake (median, 6.2% [first quartile, 1.8%; third quartile, 23.9%] vs 0.53% [first quartile, 0.33%; third quartile, 2.9%]; P = .003) and an increased RBC transfer defect (median, 20.6% [first quartile, 11.6%; third quartile, 27.8%] vs 2.8% [first quartile, 2.3%; third quartile, 4.9%]; P < .001). NSIP participants also had a reduced ratio of RBC-to-barrier peaks (median, 0.24 [first quartile, 0.19; third quartile, 0.31] vs 0.57 [first quartile, 0.52; third quartile, 0.67]; P < .001) and a reduced RBC chemical shift (median, 217.5 ppm [first quartile, 217.0 ppm; third quartile, 218.0 ppm] vs 218.2 ppm [first quartile, 217.9 ppm; third quartile, 218.6 ppm]; P = .001). Conclusion Participants with nonspecific interstitial pneumonia had increased barrier uptake and decreased red blood cell (RBC) transfer compared with healthy controls measured using xenon 129 gas-exchange MRI and reduced RBC-to-barrier ratio and RBC chemical shift measured using spectroscopy. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Wild in this issue.
引用
- Mummy DG, Bier EA, Wang Z, et al. Hyperpolarized 129Xe MRI and Spectroscopy of Gas-Exchange Abnormalities in Nonspecific Interstitial Pneumonia. Radiology. 2021. PMID: 34313473. doi:10.1148/radiol.2021204149
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。