使用0.55-T MRI系统进行T2加权肺成像
这项前瞻性研究评估了0.55-T MRI系统在肺疾病成像中的表现,并与临床CT扫描进行比较。研究纳入24名有常见肺部异常的参与者,结果显示MRI在检测支气管扩张、实变、空洞、积液、黏液栓和散在实性结节方面与CT一致性良好,但在弥漫性病变如磨玻璃影和树芽征结节方面识别较难。
要点
- 0.55-T MRI可稳健检测支气管扩张、实变、空洞、积液、黏液栓和散在实性结节。
- 磨玻璃影和树芽征结节在MRI上最难辨别,各出现4/18例假读。
- 结节大小在CT与MRI测量间强相关(R²=0.99)。
核心结论
- 这项初始研究表明,高性能0.55-T MRI在评估常见肺疾病方面具有前景。
研究设计与样本
- 前瞻性研究,2018年11月至2019年12月,纳入24名参与者(平均年龄59岁±16,18名女性),比较呼吸触发T2加权涡轮自旋回波MRI与临床CT扫描。
关键影像表现/征象
- MRI获得高质量结构肺部图像的平均采集时间为11分钟±3。
- MRI检测支气管扩张(κ=0.61)、实变影(κ=1.00)、空洞病变(κ=1.00)、积液(κ=0.64)、黏液栓(κ=0.68)和散在实性结节(κ=0.82)。
- 弥漫性疾病包括磨玻璃影(κ=0.57)和树芽征结节(κ=0.48)在MRI上最难辨别,各特征在18名患者中有4例假读。
- 结节大小在CT和MRI独立测量间强相关(R²=0.99),结节测量为10 mm±5(范围5-23 mm)。
局限性
- 这是一项初始研究,0.55-T MRI在评估常见肺疾病方面具有前景,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess a 0.55-T MRI system for imaging lung disease and to compare image quality with clinical CT scans.
MATERIALS AND METHODS: In this prospective study conducted between November 2018 and December 2019, respiratory-triggered T2-weighted turbo spin-echo MRI at 0.55 T was compared with clinical CT scans in 24 participants (mean age, 59 years ± 16 [standard deviation]; 18 women) with common lung abnormalities. MR images were reviewed and scored by experienced readers. Abnormal findings identified with MRI and CT were compared using the Cohen κ statistic.
RESULTS: High-quality structural pulmonary MR images were attained with an average acquisition time of 11 minutes ± 3. MRI generated sufficient image quality to robustly detect bronchiectasis (κ = 0.61), consolidative opacities (κ = 1.00), cavitary lesions (κ = 1.00), effusion (κ = 0.64), mucus plug (κ = 0.68), and solid scattered nodularity (κ = 0.82). Diffuse disease, including ground-glass opacities (κ = 0.57) and tree-in-bud nodules (κ = 0.48), were the findings that were most difficult to discern using MRI, with false readings in four of 18 patients for each feature. Nodule size, which was measured independently at CT and MRI, was strongly correlated (R 2 = 0.99) for nodules with a measurement of 10 mm ± 5 (range, 5-23 mm).
CONCLUSION: This initial study indicates that high-performance 0.55-T MRI holds promise in the evaluation of common lung disease.Clinical trials registration no. NCT03331380Supplemental material is available for this article. Keywords: MRI, Pulmonary, Technology Assessment© RSNA, 2021.
引用
- Campbell-Washburn AE, Malayeri AA, Jones EC, et al. T2-weighted Lung Imaging Using a 0.55-T MRI System. Radiol Cardiothorac Imaging. 2021. PMID: 34250492. doi:10.1148/ryct.2021200611
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。