视神经MRI中的运动退化:眼状态随机个体内比较研究
研究纳入接受3T眼眶MRI的患者,随机先后在睁眼注视固定点与闭眼两种状态下采集冠状STIR序列,由两位神经放射科医生用5分制评分视神经运动伪影。结果显示睁眼注视可减少前部眶内视神经运动伪影(p=0.006),而后部眶内视神经无显著差异(p=0.69)。
要点
- 睁眼注视固定点采集可减少前部眶内视神经运动伪影。
- 后部眶内视神经运动伪影在睁眼与闭眼间无显著差异。
- 评分者间信度高(加权kappa=0.78)。
核心结论
- 睁眼注视而非闭眼进行眼眶MRI可减少前部眶内视神经段的运动伪影,对后部眶内视神经未观察到类似效果。
研究设计与样本
- 随机个体内比较研究,纳入接受3T眼眶MRI的患者,共77个眼眶;采集冠状STIR序列,随机先后在睁眼注视标准化固定点(按需眨眼)与闭眼两种状态下扫描;由两位神经放射科医生采用5分制(分值越高运动伪影越重)对每根视神经的两个位置进行评分;差异采用聚类Wilcoxon符号秩检验评估;参考标准为两位阅片者评分。
关键影像表现/征象
- 前部眶内视神经:睁眼注视采集的运动伪影评分低于闭眼采集(p=0.006)。
- 后部眶内视神经:睁眼与闭眼采集的运动伪影评分无显著差异(p=0.69)。
- 前部眶内视神经:平均评分优于2分的比例睁眼为60%,闭眼为32%。
- 前部眶内视神经:平均评分4分或更差的比例睁眼为4%,闭眼为12%。
诊断标准与关键数值
- 运动伪影采用5分制评分,分值越高表示运动伪影越重。
- 两位阅片者间信度高(加权kappa=0.78)。
临床应用与阅片要点
- 作者结论提示,眼眶MRI采集时让患者睁眼并注视固定点而非闭眼,可减少前部眶内视神经运动伪影。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: MRI is a powerful tool for optic nerve assessment, but image quality can be degraded by artifacts related to ocular motion. The purpose of this investigation was to evaluate the effect of undergoing MRI with eyes open versus closed on the degree of motion degradation affecting the optic nerves.
METHOD: Patients undergoing 3 Tesla orbital MRI were randomized to undergo the coronal STIR sequence with eyes open and focused on a standardized fixation point, blinking as needed, or with eyes closed. The sequence was then performed again with the other instruction set. Two neuroradiologists rated the intraorbital optic nerves for motion artifact on a 5-point scale (higher numbers reflecting greater motion artifact) in 2 locations of each nerve. Differences were evaluated by the clustered Wilcoxon signed rank test.
RESULTS: Seventy-seven orbits were included. Interrater reliability was high (weighted kappa = 0.78). The anterior intraorbital optic nerves were rated with less motion artifact when eyes were open and focused during acquisition than when closed (p = 0.006), but this was not the case for the posterior intraorbital optic nerve (p = 0.69). For example, at the anterior intraorbital optic nerve, motion artifact of mean grade better than 2 was seen in 60% of eyes-open vs. 32% of eyes-closed acquisitions, while mean grade 4 or worse was seen in 4% of eyes-open vs. 12% of eyes-closed acquisitions.
CONCLUSION: Undergoing orbital MRI with eyes open and focused rather than closed reduces motion artifact at the anterior intraorbital segment of the optic nerve.
引用
- Deng F, Reinshagen KL, Li MD, et al. Motion degradation in optic nerve MRI: A randomized intraindividual comparison study of eye states. Eur J Radiol. 2021. PMID: 34298389. doi:10.1016/j.ejrad.2021.109865
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。