超快速波控并行成像三维FLAIR序列在脑白质病变显示与体积评估中的评价
研究纳入42例连续患者行3T脑MR,对比标准3D-FLAIR与分辨率匹配的超快速Wave-FLAIR序列(20通道线圈加速因子6、扫描2分45秒;32通道线圈加速因子9、扫描1分50秒)。结果显示两序列病灶体积一致性极佳(ICC 0.99,Dice 0.97),Wave-FLAIR在幕下病灶显示上诊断质量略高于标准FLAIR(P < .001),且搏动伪影更少(P < .001)。
要点
- Wave-FLAIR与标准FLAIR病灶体积一致性极佳,ICC 0.99,平均Dice系数0.97(SD 0.05)。
- 幕下病灶诊断质量Wave-FLAIR略高于标准FLAIR(P < .001),搏动伪影更少(P < .001)。
- Wave-FLAIR扫描时间2分45秒(20通道)或1分50秒(32通道),标准FLAIR为7分50秒。
核心结论
- 超快速Wave-FLAIR在保持整体诊断质量的同时,对幕下病灶显示优于标准FLAIR,且所测白质病变体积与标准FLAIR相当。
研究设计与样本
- 前瞻性临床对照研究,纳入42例连续患者,行3T脑MR,包括标准3D-FLAIR(加速因子2,扫描时间7分50秒)与分辨率匹配的超快速Wave-FLAIR(20通道线圈加速因子6、扫描时间2分45秒;32通道线圈加速因子9、扫描时间1分50秒),作为脱髓鞘疾病临床评估的一部分。
关键影像表现/征象
- Wave-FLAIR与标准FLAIR显示病灶体积一致性极佳,组内相关系数0.99,平均Dice相似系数0.97(SD 0.05)(范围0.84-0.99)。
- Wave-FLAIR在病灶显示和运动方面不劣于标准FLAIR。
- 幕下病灶的诊断质量Wave-FLAIR略高于标准FLAIR(P < .001)。
- Wave-FLAIR的搏动伪影少于标准FLAIR(P < .001)。
诊断标准与关键数值
- 两名盲法神经放射科医师采用预定义5分制量表评估白质病灶显示、伪影和整体诊断质量。
- 采用SPM中的Lesion Segmentation Tool自动分割脑白质病灶。
- 使用Student t检验、组内相关系数、相对病灶体积差异和Dice相似系数比较各序列的体积测量。
临床应用与阅片要点
- 超快速Wave-FLAIR的可用性可能促进3D-FLAIR序列在疑似脱髓鞘疾病患者评估中的更广泛使用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Our aim was to evaluate an ultrafast 3D-FLAIR sequence using Wave-controlled aliasing in parallel imaging encoding (Wave-FLAIR) compared with standard 3D-FLAIR in the visualization and volumetric estimation of cerebral white matter lesions in a clinical setting.
MATERIALS AND METHODS: Forty-two consecutive patients underwent 3T brain MR imaging, including standard 3D-FLAIR (acceleration factor = 2, scan time = 7 minutes 50 seconds) and resolution-matched ultrafast Wave-FLAIR sequences (acceleration factor = 6, scan time = 2 minutes 45 seconds for the 20-channel coil; acceleration factor = 9, scan time = 1 minute 50 seconds for the 32-channel coil) as part of clinical evaluation for demyelinating disease. Automated segmentation of cerebral white matter lesions was performed using the Lesion Segmentation Tool in SPM. Student t tests, intraclass correlation coefficients, relative lesion volume difference, and Dice similarity coefficients were used to compare volumetric measurements among sequences. Two blinded neuroradiologists evaluated the visualization of white matter lesions, artifacts, and overall diagnostic quality using a predefined 5-point scale.
RESULTS: Standard and Wave-FLAIR sequences showed excellent agreement of lesion volumes with an intraclass correlation coefficient of 0.99 and mean Dice similarity coefficient of 0.97 (SD, 0.05) (range, 0.84-0.99). Wave-FLAIR was noninferior to standard FLAIR for visualization of lesions and motion. The diagnostic quality for Wave-FLAIR was slightly greater than for standard FLAIR for infratentorial lesions (P < .001), and there were fewer pulsation artifacts on Wave-FLAIR compared with standard FLAIR (P < .001).
CONCLUSIONS: Ultrafast Wave-FLAIR provides superior visualization of infratentorial lesions while preserving overall diagnostic quality and yields white matter lesion volumes comparable with those estimated using standard FLAIR. The availability of ultrafast Wave-FLAIR may facilitate the greater use of 3D-FLAIR sequences in the evaluation of patients with suspected demyelinating disease.
引用
- Ngamsombat C, Gonçalves Filho ALM, Longo MGF, et al. Evaluation of Ultrafast Wave-Controlled Aliasing in Parallel Imaging 3D-FLAIR in the Visualization and Volumetric Estimation of Cerebral White Matter Lesions. AJNR Am J Neuroradiol. 2021. PMID: 34244127. doi:10.3174/ajnr.A7191
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。