短暂性全面性遗忘患者脑磁共振扩散加权成像诊断率:系统评价与Meta分析
该系统评价与Meta分析纳入22篇原始研究共1732例短暂性全面性遗忘患者,汇总DWI诊断率为39%(95%CI 27-52%),异质性I²=95%;层厚≤3mm的DWI诊断率高于层厚>3mm(63% vs 26%,p<0.01),症状发作后24至96小时行DWI诊断率(68%)高于24小时内(16%)或晚于96小时(15%),3T与1.5T之间无差异。
要点
- TGA患者DWI总体诊断率为39%(95%CI 27-52%),异质性I²=95%。
- 层厚≤3mm的DWI诊断率63%,高于层厚>3mm的26%(p<0.01)。
- 症状发作后24至96小时行DWI诊断率68%,高于24小时内16%或晚于96小时15%(p<0.01)。
核心结论
- TGA患者DWI汇总诊断率为39%;层厚≤3mm或症状发作后>24至96小时行DWI可提高诊断率。
研究设计与样本
- 系统评价与Meta分析,检索MEDLINE和EMBASE数据库,纳入22篇原始研究共1732例TGA患者,采用DerSimonian-Laird随机效应模型计算汇总诊断率,并按层厚、磁场强度和症状发作至DWI间隔进行亚组分析。
关键影像表现/征象
- 右侧海马病灶占所有病灶的37%(95%CI 30-44%)。
- 左侧海马病灶占所有病灶的42%(95%CI 39-46%)。
- 双侧海马病灶占所有病灶的25%(95%CI 20-30%)。
诊断标准与关键数值
- DWI在TGA患者中的汇总诊断率为39%(95%CI 27-52%),Higgins I²=95%。
- 层厚≤3mm的DWI汇总诊断率为63%(95%CI 53-72%),层厚>3mm为26%(95%CI 16-40%),p<0.01。
- 症状发作后24至96小时行DWI汇总诊断率为68%(95%CI 57-78%),高于24小时内16%(95%CI 7-34%)或晚于96小时15%(95%CI 8-26%),p<0.01。
- 3T与1.5T DWI汇总诊断率分别为31%(95%CI 25-38%)与24%(95%CI 14-37%),p=0.31,无差异。
临床应用与阅片要点
- 原文结论指出层厚≤3mm或症状发作后>24至96小时行DWI可提高TGA诊断率。
局限性
- Higgins I²统计量显示显著异质性(I²=95%)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield.
MATERIALS AND METHODS: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI.
RESULTS: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I² statistic showed significant heterogeneity (I² = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31).
CONCLUSION: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.
引用
- Lim SJ, Kim M, Suh CH, et al. Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis. Korean J Radiol. 2021. PMID: 34269537. doi:10.3348/kjr.2020.1462
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。