静磁场抑制聚焦超声介导的血脑屏障开放

Static Magnetic Fields Dampen Focused Ultrasound-mediated Blood-Brain Barrier Opening.
PubMed 文献 · Radiology · 2021-07-06

研究用30只野生型小鼠分四组,在约0、1.5、3.0、4.7 T静磁场中行聚焦超声联合微泡开放血脑屏障。静磁场使微泡空化剂量降低、血脑屏障开放体积减小、伊文思蓝跨血脑屏障递送减少。

要点

  • MRI静磁场降低聚焦超声联合微泡的空化活性,场强越高降低越明显。
  • 静磁场减小血脑屏障开放体积,4.7 T时减小幅度最大。
  • 静磁场减少伊文思蓝跨血脑屏障递送,递送效率随场强升高而下降。

核心结论

  • 静磁场抑制微泡空化活性,并减少聚焦超声联合微泡所致血脑屏障开放后的跨血脑屏障递送。

研究设计与样本

  • 动物实验,30只野生型小鼠分四组,分别在约0、1.5、3.0、4.7 T静磁场中行聚焦超声声辐照,其余实验参数保持一致;静脉注射微泡后声辐照,被动空化检测监测空化活动,声辐照后行增强T1加权MRI评估血脑屏障开放,静脉注射伊文思蓝评估跨血脑屏障递送效率。

诊断标准与关键数值

  • 与约0 T磁场外相比,微泡空化剂量在1.5 T平均降低2.1 dB(P = .05),3.0 T降低2.9 dB(P = .01),4.7 T降低3.0 dB(P = .01)。
  • 与磁场外处理小鼠相比,血脑屏障开放体积在1.5 T减小3.2倍(P < .001),3.0 T减小4.5倍(P < .001),4.7 T减小11.6倍(P < .001)。
  • 与磁场外处理小鼠相比,伊文思蓝跨血脑屏障递送在1.5 T减少1.4倍(P = .009),3.0 T减少1.6倍(P < .001),4.7 T减少1.9倍(P < .001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening in conjunction with MRI. However, the impact of the static magnetic field generated by an MRI scanner on the BBB opening outcome has not been evaluated. Purpose To determine the relationship of the static magnetic field of an MRI scanner on focused ultrasound combined with microbubble-induced BBB opening. Materials and Methods Thirty wild-type mice were divided into four groups. Mice from different groups were sonicated with focused ultrasound in different static magnetic fields (approximately 0, 1.5, 3.0, and 4.7 T), with all other experimental parameters kept the same. Focused ultrasound sonication was performed after intravenous injection of microbubbles. Microbubble cavitation activity, the fundamental -physical mechanism underlying focused ultrasound BBB opening, was monitored with passive cavitation detection. After sonication, contrast-enhanced T1-weighted MRI was performed to assess BBB opening outcome. Intravenously injected Evans blue was used as a model agent to evaluate trans-BBB delivery efficiency. Results The microbubble cavitation dose decreased by an average of 2.1 dB at 1.5 T (P = .05), 2.9 dB at 3.0 T (P = .01), and 3.0 dB at 4.7 T (P = .01) compared with that outside the magnetic field (approximately 0 T). The static magnetic field of an MRI scanner decreased BBB opening volume in mice by 3.2-fold at 1.5 T (P < .001), 4.5-fold at 3.0 T (P < .001), and 11.6-fold at 4.7 T (P <.001) compared with mice treated outside the magnetic field. It also decreased Evans blue trans-BBB delivery 1.4-fold at 1.5 T (P = .009), 1.6-fold at 3.0 T (P < .001), and 1.9-fold at 4.7 T (P < .001). Conclusion Static magnetic fields dampened microbubble cavitation activity and decreased trans-blood-brain barrier (BBB) delivery by focused ultrasound combined with microbubble-induced BBB opening. © RSNA, 2021 An earlier incorrect version of this article appeared online. This article was corrected on July 8, 2021.