文献速递神经MR

合成MRI在蛛网膜下腔出血中的应用

Synthetic MRI in subarachnoid haemorrhage.
PubMed 文献 · Clin Radiol · 2021-06-27

本研究纳入20例蛛网膜下腔出血患者,在3 T MRI上对比常规脑MRI与合成MRI(SyMRI)的T2加权FLAIR图像,评估缺血灶、脑积水、轴外积血及灰质、白质、脑脊液体积。两种技术对缺血灶和轴外积血的检出一致性极好(kappa分别为0.80和0.88),对脑积水一致性良好(kappa=0.69);SyMRI采集时间较常规MRI缩短。结论认为SyMRI能以与常规MRI相似的方式检出蛛网膜下腔出血的潜在并发症,且采集时间更短。

要点

  • SyMRI与常规MRI对蛛网膜下腔出血后缺血灶检出的一致性极好(kappa=0.80)。
  • SyMRI与常规MRI对轴外积血检出的一致性极好(kappa=0.88),对脑积水一致性良好(kappa=0.69)。
  • SyMRI采集时间较常规MRI缩短,4 mm层厚时缩短32%,3 mm层厚时缩短6%。

核心结论

  • SyMRI能以与常规MRI相似的方式检出蛛网膜下腔出血的潜在并发症,且采集时间更短。

研究设计与样本

  • 研究纳入20例蛛网膜下腔出血患者,在3 T MRI机上先后行常规脑MRI与SyMRI检查,采集可比的常规与合成T2加权FLAIR图像,比较缺血灶、脑积水、轴外积血及灰质体积、白质体积、脑脊液体积,并分析两种序列的采集时间。

关键影像表现/征象

  • SyMRI与常规MRI对缺血灶检出的一致性极好(kappa=0.80)。
  • SyMRI与常规MRI对轴外积血检出的一致性极好(kappa=0.88)。
  • SyMRI与常规MRI对脑积水检出的一致性良好(kappa=0.69)。

诊断标准与关键数值

  • 缺血灶数目在两种技术间无显著差异(p=0.31)。
  • Evans指数在两种技术间无显著差异(p=0.11)。
  • 白质体积在两种技术间无显著差异(p=0.18),脑脊液体积在两种技术间无显著差异(p=0.94)。
  • 缺血灶体积在两种技术间无显著差异(p=0.79)。
  • 与常规MRI相比,SyMRI采集时间在4 mm层厚时缩短32%,在3 mm层厚时缩短6%。

临床应用与阅片要点

  • SyMRI可在较短采集时间内获得与常规MRI相似的T2加权FLAIR图像,用于评估蛛网膜下腔出血后缺血灶、脑积水和轴外积血。
  • 阅片时对脑积水的评估一致性为良好(kappa=0.69),低于缺血灶和轴外积血的一致性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the reliability of synthetic magnetic resonance imaging (SyMRI) for detecting complications associated with subarachnoid haemorrhage (SAH), such as ischaemic lesions, hydrocephalus, or bleeding complications.

MATERIALS AND METHODS: Twenty patients with SAH, who underwent a conventional brain MRI and a SyMRI on a 3 T MRI machine. Comparable conventional and synthetic T2-weighted fluid attenuated inversion recovery (FLAIR) images were acquired. The presence of ischaemic lesions, hydrocephalus, extra-axial blood collections as well as the volumes of grey matter (GMv), white matter (WMv), and cerebrospinal (CSFv) were compared. The acquisition times of both sequences was also analysed.

RESULTS: The concordance between the two techniques was excellent for the detection of ischaemic lesions and extra-axial collections (kappa = 0.80 and 0.88 respectively) and good for the detection of hydrocephalus (kappa = 0.69). No significant differences were detected in the number of ischaemic lesions (p=0.31) or in the Evans index (p=0.11). The WMv and CSFv measures were also similar (p=0.18 and p=0.94, respectively), as well as the volume of ischaemic lesions (p=0.79). Compared to conventional MRI, the SyMRI acquisition time was shorter regardless of the number of sections (32% and 6% time reduction for 4 or 3 mm section thickness, respectively).

CONCLUSIONS: SyMRI allows the detection of potential complications of SAH in a similar way to conventional MRI with a shorter acquisition time.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Montejo C, Laredo C, Llull L, et al. Synthetic MRI in subarachnoid haemorrhage. Clin Radiol. 2021. PMID: 34193343. doi:10.1016/j.crad.2021.05.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。