文献速递胸部外周血管技术与安全CT

基于深度学习的CT肺动脉造影肺栓塞自动检测:技术实施九个月后对报告沟通时间和急诊患者周转无显著影响

Deep learning-based automated detection of pulmonary embolism on CT pulmonary angiograms: No significant effects on report communication times and patient turnaround in the emergency department nine months after technical implementation.
PubMed 文献 · Eur J Radiol · 2021-06-11

本研究分析了2018年4月至2020年6月间1808例CT肺动脉造影,评估深度学习自动检测肺栓塞联合工作列表优先排序和电子通知系统对急诊报告阅读时间、沟通时间、抗凝启动时间和患者周转时间的影响。算法敏感度79.6%、特异度95.0%、阳性预测值82.2%、阴性预测值94.1%,但所有观察时间均无统计学显著缩短。结论认为工具技术可行,但仅临床引入不足以显著改善临床绩效指标。

要点

  • 算法在检查水平敏感度79.6%、特异度95.0%,阳性预测值82.2%、阴性预测值94.1%。
  • 深度学习检测联合电子通知系统未显著缩短报告阅读、沟通、抗凝启动或急诊周转时间。
  • 技术实施本身不足以改善临床绩效指标,需关注流程整合。

核心结论

  • 深度学习辅助肺栓塞检测和电子通知系统技术可行,但仅临床引入这些工具即使性能良好,也不足以对临床绩效指标产生显著影响。

研究设计与样本

  • 研究分析了2018年4月至2020年6月间1808例CT肺动脉造影,比较三个连续时间段,以书面报告和检查复核为参考标准计算算法性能。

诊断标准与关键数值

  • 算法在检查水平敏感度79.6%(95%CI:70.8-87.2%)、特异度95.0%(95%CI:92.0-97.1%)、阳性预测值82.2%(95%CI:73.9-88.3)、阴性预测值94.1%(95%CI:91.4-96%),以书面报告和检查复核为参考标准。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Rapid communication of CT exams positive for pulmonary embolism (PE) is crucial for timely initiation of anticoagulation and patient outcome. It is unknown if deep learning automated detection of PE on CT Pulmonary Angiograms (CTPA) in combination with worklist prioritization and an electronic notification system (ENS) can improve communication times and patient turnaround in the Emergency Department (ED).

METHODS: In 01/2019, an ENS allowing direct communication between radiology and ED was installed. Starting in 10/2019, CTPAs were processed by a deep learning (DL)-powered algorithm for detection of PE. CTPAs acquired between 04/2018 and 06/2020 (n = 1808) were analysed. To assess the impact of the ENS and the DL-algorithm, radiology report reading times (RRT), radiology report communication time (RCT), time to anticoagulation (TTA), and patient turnaround times (TAT) in the ED were compared for three consecutive time periods. Performance measures of the algorithm were calculated on a per exam level (sensitivity, specificity, PPV, NPV, F1-score), with written reports and exam review as ground truth.

RESULTS: Sensitivity of the algorithm was 79.6 % (95 %CI:70.8-87.2%), specificity 95.0 % (95 %CI:92.0-97.1%), PPV 82.2 % (95 %CI:73.9-88.3), and NPV 94.1 % (95 %CI:91.4-96 %). There was no statistically significant reduction of any of the observed times (RRT, RCT, TTA, TAT).

CONCLUSION: DL-assisted detection of PE in CTPAs and ENS-assisted communication of results to referring physicians technically work. However, the mere clinical introduction of these tools, even if they exhibit a good performance, is not sufficient to achieve significant effects on clinical performance measures.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Schmuelling L, Franzeck FC, Nickel CH, et al. Deep learning-based automated detection of pulmonary embolism on CT pulmonary angiograms: No significant effects on report communication times and patient turnaround in the emergency department nine months after technical implementation. Eur J Radiol. 2021. PMID: 34157638. doi:10.1016/j.ejrad.2021.109816

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。