文献速递骨肌神经MR

Dixon T2加权水脂分离水像序列上的脊神经信号强度:腰椎经椎间孔硬膜外注射后结局的重要预测指标

Spinal nerve signal intensity on Dixon T2-weighted water-only sequence: an important outcome predictor after lumbar transforaminal epidural injection.
PubMed 文献 · Eur Radiol · 2021-06-16

研究纳入94例在MRI检查后3个月内接受单根脊神经经椎间孔硬膜外注射的患者,按注射反应分为阳性结局组76例与阴性结局组18例。阳性结局组注射侧脊神经平均信号强度及神经-脂肪信号比均显著高于阴性结局组(793.78 vs. 679.19,p=0.016;4.21 vs. 3.28,p=0.003)。结论认为轴位Dixon T2加权水像上脊神经平均信号强度和神经-脂肪信号比有助于预测患者对经椎间孔硬膜外注射的反应。

要点

  • 轴位Dixon T2加权水像上注射侧脊神经信号强度较高提示经椎间孔硬膜外注射结局较好。
  • 神经-脂肪信号比在阳性结局组为4.21、阴性结局组为3.28,两组差异有统计学意义(p=0.003)。
  • 阳性结局组注射侧脊神经直径大于对侧(6.91 mm vs. 6.37 mm,p=0.016)。

核心结论

  • 轴位Dixon T2加权水像上脊神经平均信号强度和神经-脂肪信号比可帮助预测患者对经椎间孔硬膜外注射的反应。

研究设计与样本

  • 研究纳入2018年8月至2020年4月间在MRI检查后3个月内接受单根脊神经经椎间孔硬膜外注射的患者94例,按注射反应分为阳性结局组76例和阴性结局组18例;由两名骨肌放射科医师在术前轴位Dixon T2加权水像上测量注射侧脊神经、对侧脊神经及皮下脂肪信号强度,并在轴位Dixon T2加权同相位像上测量脊神经直径。

关键影像表现/征象

  • 阳性结局组注射侧脊神经平均信号强度为793.78,阴性结局组为679.19,阳性结局组更高(p=0.016)。
  • 阳性结局组注射侧脊神经神经-脂肪信号比为4.21,阴性结局组为3.28,阳性结局组更高(p=0.003)。
  • 阳性结局组注射侧脊神经直径为6.91 mm,对侧为6.37 mm,注射侧大于对侧(p=0.016)。

诊断标准与关键数值

  • 以经椎间孔硬膜外注射术后的反应将患者分为阳性结局组与阴性结局组。
  • 轴位Dixon T2加权水像上注射侧脊神经平均信号强度阳性结局组793.78 vs. 阴性结局组679.19(p=0.016)。
  • 轴位Dixon T2加权水像上注射侧脊神经神经-脂肪信号比阳性结局组4.21 vs. 阴性结局组3.28(p=0.003)。
  • 轴位Dixon T2加权同相位像上阳性结局组注射侧脊神经直径6.91 mm vs. 对侧6.37 mm(p=0.016)。

临床应用与阅片要点

  • 在腰椎MRI中应用Dixon技术有助于预测患者对经椎间孔硬膜外注射操作的反应。
  • 轴位Dixon T2加权水像上神经-脂肪信号比和脊神经平均信号强度升高提示经椎间孔硬膜外注射结局较好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the role of Dixon T2-weighted water-fat separation technique in predicting the outcome of lumbar transforaminal epidural injections (TFESIs).

METHODS: Patients who underwent TFESI of a single spinal nerve within 3 months after magnetic resonance imaging (MRI) exam between August 2018 and April 2020 were identified. The patients were classified into positive or negative outcome groups based on the response to the TFESI procedure. Two musculoskeletal radiologists measured the signal intensity of the injected side spinal nerves, contralateral side spinal nerves, and subcutaneous fat on axial Dixon T2-weighted water-only images, and the diameter of spinal nerve on axial Dixon T2-weighted in-phase images of the pre-procedural MRI. The measured values of the injected side spinal nerves were compared between the two groups and with the contralateral side spinal nerve.

RESULTS: A total of 94 patients were included, 76 in the positive outcome group and 18 in the negative outcome group. The mean signal intensity and the nerve-to-fat signal ratio of the injected side spinal nerve were significantly higher in the positive outcome group than in the negative outcome group (793.78 vs. 679.19, p = 0.016; 4.21 vs. 3.28, p = 0.003). In the positive outcome group, the diameter of the spinal nerve was significantly higher on the injected side than on the contralateral side (6.91 mm vs. 6.37 mm, p = 0.016).

CONCLUSIONS: The mean signal intensity and the nerve-to-fat signal ratio of the spinal nerve on axial Dixon T2-weighted water-only images can help predict patient response to the TFESI.

KEY POINTS: • Applying the Dixon technique to lumbar spine MRI can help predict patient response to the TFESI procedure. • An increased nerve-to-fat signal ratio and mean spinal nerve signal intensity on axial Dixon T2-weighted water-only images predicted favorable TFESI outcomes.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim YH, Kim HJ, Seo J, et al. Spinal nerve signal intensity on Dixon T2-weighted water-only sequence: an important outcome predictor after lumbar transforaminal epidural injection. Eur Radiol. 2021. PMID: 34132874. doi:10.1007/s00330-021-08119-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。