膝关节腓侧副韧带近端影像学特征:超声与MRI表现及组织学对照
这项前瞻性研究对73例受试者共77次膝关节检查行MRI与超声评估,并对照两例尸体膝关节组织学。MRI上腓侧副韧带近端信号增高常见(中等信号占75%),超声上低回声占38%,两种方法间信度良好(ICC 0.735-0.899);组织学显示韧带纤维向纤维软骨过渡伴结缔组织黏蛋白增多,与影像表现对应。结论认为腓侧副韧带近端信号增高常见,对应正常结缔组织黏蛋白。
要点
- MRI上腓侧副韧带近端中等信号占75%(58/77),属常见表现。
- 超声上腓侧副韧带近端低回声占38%(29/77),不可误判为撕裂。
- 组织学证实信号/回声改变对应正常结缔组织黏蛋白沉积。
核心结论
- 腓侧副韧带近端在超声和MRI上的信号增高常见,对应正常结缔组织黏蛋白。
研究设计与样本
- 前瞻性研究,经IRB批准并获知情同意,共纳入73例受试者(39男、34女,平均年龄48±14岁)的77次膝关节检查。
- 患者行膝关节MRI后额外接受超声评估,评估腓侧副韧带信号强度、回声及范围。
- 对两例尸体膝关节行MRI和超声检查,并做腓侧副韧带组织学评估作为对照。
关键影像表现/征象
- MRI上腓侧副韧带信号为低、中等、高者分别占21%(16/77)、75%(58/77)、4%(3/77)。
- 超声上回声为高回声、低回声、无回声者分别占62%(48/77)、38%(29/77)、0%(0/77)。
- 信号增高范围平均长度MRI为8.6 mm(±4.9),超声为6.5 mm(±4.8)。
- 组织学显示韧带纤维在附着处向纤维软骨过渡,结缔组织黏蛋白增多,与MRI和超声表现对应。
诊断标准与关键数值
- MRI信号强度分级:低信号、中等信号、高信号。
- 超声回声分级:高回声、低回声、无回声。
- 两种方法间信度ICC为0.735-0.899,属良好至优秀。
- 读者间测量差异无统计学显著性(P=.163-.795)。
临床应用与阅片要点
- 阅片时需注意腓侧副韧带近端MRI中等信号和超声低回声可为正常表现,对应结缔组织黏蛋白。
- 评估腓侧副韧带时应结合信号/回声改变的部位与范围,避免将生理性信号增高误判为病变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Determine prevalence of increased signal intensity of the lateral collateral ligament (LCL) of the knee on MRI and decreased echogenicity on ultrasound, and compare with cadaveric histologic evaluation.
METHODS: After IRB approval of this prospective study with informed consent, patients having knee MRI were additionally evaluated with ultrasound. Signal intensities of LCL on MRI (low, intermediate, high), echogenicity at ultrasound (hyperechoic, hypoechoic, anechoic), and extent of findings were assessed. Descriptive statistics, Wilcoxon signed ranked test, and intraclass correlation coefficient (ICC) were calculated. Two cadaveric knees were imaged with MRI and ultrasound, including histologic LCL evaluation.
RESULTS: Seventy-three subjects were included (39 males, 34 females; mean age 48 ± 14 years) with 77 knee examinations. On MRI, low, intermediate, and high signals were present in 21% (16/77), 75% (58/77), and 4% (3/77), respectively. On ultrasound, echogenicity was assessed as hyperechoic, hypoechoic, and anechoic in 62% (48/77), 38% (29/77), and 0% (0/77), respectively. Mean length of increased signal was 8.6 mm (±4.9) on MRI, and 6.5 mm (±4.8) on ultrasound. The ICC showed a good to excellent intermodality reliability (0.735-0.899) without statistically significant difference for interreader measurements (P = .163-.795). Histology evaluation showed transition of ligament fibers to fibrocartilage at its insertion with increased connective tissue mucin corresponding to MRI and ultrasound findings.
CONCLUSIONS: Increased signal intensity of the proximal LCL on ultrasound and MRI is common and corresponds to normal connective tissue mucin.
引用
- Falkowski AL, Jacobson JA, Gandikota G, et al. Imaging Characteristics of the Proximal Lateral Collateral Ligament of the Knee: Findings on Ultrasound and MRI With Histologic Correlation. J Ultrasound Med. 2021. PMID: 34086999. doi:10.1002/jum.15761
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。