改良版韩国甲状腺影像报告与数据系统对甲状腺恶性结节的诊断效能:多中心验证研究
基于韩国甲状腺影像网络26家机构5081例患者5708个≥1.0 cm甲状腺结节,回顾性评估改良版K-TIRADS与2016版K-TIRADS的诊断效能。改良版K-TIRADS通过提高活检尺寸阈值和细分4类亚类,降低了小结节(1-2 cm)的不必要活检率,同时对大结节(>2 cm)保持98%的高敏感度。
要点
- 改良版K-TIRADS 2将4类细分为4A和4B,4B活检阈值1 cm、4A阈值1.5 cm。
- 小结节(1-2 cm)中改良版K-TIRADS敏感度较2016版降低5.2-25.6%,不必要活检率降低19.2-32.8%(p<0.001)。
- 大结节(>2 cm)中改良版K-TIRADS对恶性结节的敏感度维持在98%。
核心结论
- 改良版K-TIRADS显著降低了小结节(1-2 cm)的不必要活检率,同时对大结节(>2 cm)维持对恶性结节很高的敏感度。
研究设计与样本
- 多中心回顾性研究,2015年6月至9月期间在26家机构连续纳入5081例患者共5708个≥1.0 cm甲状腺结节,均行甲状腺超声检查;以活检为参考标准。
诊断标准与关键数值
- 2016版K-TIRADS:敏感度94.9%、特异度24.4%、良性结节不必要活检率60.9%;改良版K-TIRADS 1:敏感度91.0%、特异度39.7%、不必要活检率48.6%;改良版K-TIRADS 2:敏感度84.9%、特异度45.9%、不必要活检率43.5%;改良版K-TIRADS 3:敏感度76.1%、特异度50.2%、不必要活检率40.1%。改良版K-TIRADS 1对K-TIRADS 3和4的活检尺寸阈值分别为2 cm和1 cm;改良版K-TIRADS 3对K-TIRADS 4的活检尺寸阈值为1.5 cm;改良版K-TIRADS 2将K-TIRADS 4细分为4A和4B,活检尺寸阈值分别为1.5 cm和1 cm。
临床应用与阅片要点
- 作者结论认为改良版K-TIRADS可显著降低小结节(1-2 cm)的不必要活检率,同时对大结节(>2 cm)维持很高的恶性敏感度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS), and compare it with the 2016 version of K-TIRADS using the Thyroid Imaging Network of Korea.
MATERIALS AND METHODS: Between June and September 2015, 5708 thyroid nodules (≥ 1.0 cm) from 5081 consecutive patients who had undergone thyroid ultrasonography at 26 institutions were retrospectively evaluated. We used a biopsy size threshold of 2 cm for K-TIRADS 3 and 1 cm for K-TIRADS 4 (modified K-TIRADS 1) or 1.5 cm for K-TIRADS 4 (modified K-TIRADS 3). The modified K-TIRADS 2 subcategorized the K-TIRADS 4 into 4A and 4B, and the cutoff sizes for the biopsies were defined as 1 cm for K-TIRADS 4B and 1.5 cm for K-TIRADS 4A. The diagnostic performance and the rate of unnecessary biopsies of the modified K-TIRADS for detecting malignancy were compared with those of the 2016 K-TIRAD, which were stratified by nodule size (with a threshold of 2 cm).
RESULTS: A total of 1111 malignant nodules and 4597 benign nodules were included. The sensitivity, specificity, and unnecessary biopsy rate of the benign nodules were 94.9%, 24.4%, and 60.9% for the 2016 K-TIRADS; 91.0%, 39.7%, and 48.6% for the modified K-TIRADS 1; 84.9%, 45.9%, and 43.5% for the modified K-TIRADS 2; and 76.1%, 50.2%, and 40.1% for the modified K-TIRADS 3. For small nodules (1-2 cm), the diagnostic sensitivity of the modified K-TIRADS decreased by 5.2-25.6% and the rate of unnecessary biopsies reduced by 19.2-32.8% compared with those of the 2016 K-TIRADS (p < 0.001). For large nodules (> 2 cm), the modified K-TIRADSs maintained a very high sensitivity for detecting malignancy (98%).
CONCLUSION: The modified K-TIRADSs significantly reduced the rate of unnecessary biopsies for small (1-2 cm) nodules while maintaining a very high sensitivity for malignancy for large (> 2 cm) nodules.
引用
- Chung SR, Ahn HS, Choi YJ, et al. Diagnostic Performance of the Modified Korean Thyroid Imaging Reporting and Data System for Thyroid Malignancy: A Multicenter Validation Study. Korean J Radiol. 2021. PMID: 34132082. doi:10.3348/kjr.2021.0230
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。